SPECIFICATIONS
MOUNTING POSITIONS
Upright, 90 from upright or vertical
UPRIGHT
LEFT OR RIGHT
NOTE: Control shown may not be identical to replacement control
Figure 1. Gas Valve Mounting Positions
PRECAUTIONS
DO NOT BEGIN INSTALLATION UNTIL YOU READ THE FOLLOWING
PRECAUTIONS.
WARNING
!
1. Failure to turn off electric or main gas sup-
ply to heating system could cause personal
injury and/or property damage by shock, gas
suffocation, fire, and/or explosion.
2. Do not use this control on circuits exceeding
specified voltage. Higher voltage will dam-
age the control and may cause shock or fire
hazard.
3. NEVER USE FLAME OR ANY KIND OF SPARK
TO CHECK FOR GAS LEAKS–COULD CAUSE
FIRE AND/OR EXPLOSION.
4. DO NOT USE WIRE JUMPER on pilot sys-
tems, such as standing pilot, proven pilot,
or spark-to-pilot ignition–a fire and/or explo-
sion may result.
Properly install gas piping to control.
• Do not remove protective inlet or outlet caps until ready to connect supply pipe to gas valve.
• Use new supply pipe, properly threaded, reamed, de-burred, and cleaned.
• Use backup wrench, applied only to provided wrench flats on inlet boss, when tightening the
supply pipe. Do not grip bracket, solenoid or any other part of control.
• Do not over-tighten pipe to control (50 ft-lbs max.)
• Always install sediment trap in the gas supply line to prevent contamination of gas valve.
Failure to install properly can cause gas leakage resulting in injury due to fire or explosion.
1. Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring
can cause equipment damage, property damage, and/or personal injury.
2. This control is not intended for use in locations where it may come in direct contact with water.
Suitable protection must be provided to shield the control from exposure to water (dripping,
spraying, rain, etc.).
3. Clean gas piping of contaminants, cutting fluid, or other chemicals which might react harm-
fully with the gas valve components before install.
2
INLET BOSS
UP OR DOWN
ON
If you do not follow these instructions exactly, a fire or explosion
may result, causing property damage, personal injury or loss of life.
5. Do not use a control set for natural gas with LP
6. Do not use a gas valve which appears to
7. Do not use a gas valve that has been in direct
WARNING
!
CAUTION
!
Figure 2. Valve Dimensions
gas, or a control set for LP gas with natural gas.
Personal injury and/or property damage, gas
suffocation, fire, and/or explosion may result.
be damaged. A damaged valve may cause
personal injury and/or property damage
due to shock, gas suffocation, fire and/or
explosion. Contact supplier to replace any
valve that appears to have been damaged.
contact with water. Water entering gas valve
may result in concealed internal damage to
gas valve. Personal injury and/or property
damage, gas suffocation, fire and/or explo-
sion may result.