SYSTEM WIRING

All wiring should be installed in accordance with local and national electrical codes and ordinances.
Always check that the electrical power supply used agrees with the voltage and frequency shown on the
gas control.
The typical wiring diagram shows only the terminal identification and wiring hook up. Always refer to
wiring instructions provided by Equipment Manufacturer for system hookup operation.
Jumper
NOTE: If appliance does not
have E.C.O. Switch
or supplementary limit,
jumper E.C.O. terminals
For appliances with an Electrical Cut Out (E.C.O.)
device or supplementary high limit switch,
connect black wire from power unit to one side
of the switch. Attach the other side of the switch
to TH-PG.
Jumper
NOTE: If appliance does not
have E.C.O. Switch
or supplementary limit,
jumper E.C.O. terminals
4
Electrical Cut Out (E.C.O.) Switch or
Supplementary Limit in appliance
ECO Terminals (2)
TH, TH-TR to Thermostat
W
Thermostat
Figure 5. Wiring for 36C03 (24 VAC)
Figure 5. Wiring for 36C03(24 VAC)
TH, TH-PG to Thermostat
TH
PG
Figure 6. Wiring for 36C03U (750 millivolt Pilot Generator)
Figure 6. Wiring for 36C03U (750 millivolt Pilot Generator)
Electrical Cut Out (E.C.O.) Switch or
Supplementary Limit in appliance
ECO Terminals (2)
Figure 7. Wiring for 36C03A (120 Volt)
NOTE
Power Unit
TH
TR
TH
TR
PILOT
ADJ.
R
TH
PILOT
ADJ.
R
W
Thermostat
Power Unit
PILO
AD
Line voltage thermostat
or operating control
TH-TR, TR to Transformer
24 VAC
Transformer
For appliances without an
Electrical Cut Out (E.C.O.)
device or supplementary high
limit switch, connect black
wire from power unit to TH-PG.
PG
TH- PG
TH-PG, PG to Pilot Generator
Pilot
Generator
Line
Hot
Line
High
limit