Mark "lower" wood screw holes
locations in the wall using a
pencil.
Remove the hood.
Drive "lower" wood screws, by
hand. Remove screws.
Mount the hood onto the "upper"
screws.
Drive and tighten the "upper" wood
screws, by hand.
Drive and tighten the "lower" wood
screws, by hand.
Connecting the ductwork
Install ductwork, making connections in the direction of
airow as illustrated.
Push duct over the exhaust outlet.
Wrap all duct joints and the flange connections with duct
tape for an airtight seal.
Make the same connection in the wall or ceiling vent exit.
Duct tape
over seam
8
Airflow
Electrical Connection
I WARNING
ELECTRICAL SHOCK HAZARD.
I WARNING
TURN OFF POWER CIRCUIT AT THE SERVICE PANEL
BEFORE WIRING THIS UNIT.
120 VAC, 15 OR 20 AMP CIRCUIT REQUIRED.
ELECTRICAL GROUNDING INSTRUCTIONS
This appliance is fitted with an electrical junction box with
3 wires, one of which (green/yellow) serves to ground the
appliance.
To protect you against electric shock, the green and yellow
wire must be connected to the grounding wire in your home
electrical system, and it must under no circumstances be cut
or removed.
Failure to do so can result in death or electrical shock.
Facing the front of the range hood, remove the left knockout
and the Junction box cover and install the conduit connector
(cULus listed) in junction box.
If not already done, install
Use UL listed wire connectors and connect black wires
together.
Use UL listed wire connectors and connect white wires
together.
Connect green (or bare) ground wire from home power
supply to yellow-green ground wire in terminal box using
UL listed wire connectors.
Install terminal box cover.
UL listed
wire nut
House
wiring
Mounting the duct cover
Note: Upper Duct Cover may be placed upside down to hide
(or unhide) louver holes.
Position the duct cover over the mounted hood.
Slide the bottom of the duct into the canopy area.
Position the top of the duct over the duct mounting
bracket. If a telescopic duct cover is used, grab the upper
part of the telescopic duct cover, pull it and place it in the
duct cover mounting bracket.
Knockout
Junction
box cover
1
⁄
" conduit connector in j-box.
2
Metal
electrical
conduit