Make Electrical Connection For In-Line Blower Motor System - ELICA KIT0179549 Guía De Instalación, Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

7 Replace the front cover of the shell and fix it with the 6
screws previously retired and place the additional 10 - 6.5 x
3.5 mm screws contained on the hardware bag.
8 Install the conduit connectors and conduit to the in-line
blower housing and range hood electrical terminal boxes.
9 Connect the vent system to the range hood and in-line
blower system and seal all joints with clamps.
I WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
I WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire in
terminal box.
Failure to do so can result in death or electrical shock.
NOTE: The electrical diagram is attached at the end of the
document.
Electrical Connection Inside In-line Blower System
1
Disconnect power.
2 Connect the wires from the wiring conduit to the wires
from the motor electrical plug cable inside the in-line
blower housing terminal box.
3 Use UL listed wire connectors and connect the black wires
(C) together.
4 Use UL listed wire connectors and connect the white wires
(D) together.
5 Use UL listed wire connectors and connect the red wires
(E) together.
6 Use UL listed wire connectors and connect the blue wires
(F) together.
7 Use UL listed wire connectors and connect the gray wires
(G) together.

Make Electrical Connection for In-Line Blower Motor System

F
G
A. Vent System
B. In line Blower Motor
C. Ceiling
D. Roof rafters/ Plywood
8 Connect the green (or green/yellow) ground wire from the
wiring conduit to the green (or yellow/green), ground wire
(H) in the terminal box using UL listed wire connectors.
B
A
A. Strain relief
F. Blue wires
B. UL listed wire connectors
G. Gray wires
C. Black wires
H. Green (or yellow/ green) and green / yellow wires
D. White wires
I. Motor electrical plug cable
E. Red wires
9 Once the connection is done, is necessary to adjust the 6
wire connector with the included strap.
B
A
10 Reinstall the in-line blower terminal box cover and screws.
11 Reinstall the front cover of the in-line blower housing and
secure it with 10 mounting screws.
A
B
C
D
E
E. In line Blower Wiring Conduit (not
included)
F. Power Supply Wiring Conduit
G. Hood Insert
C
D
E
F
G
H
I
D
A. Ground wires connection
B. 6-9 wire connector
C. Strap
C
D. Strain relief
13

Publicidad

Tabla de contenido
loading

Tabla de contenido