Figure 15 - 120 VAC, 30 Amp Receptacle
2.4 AUTOMATIC IDLE CONTROL (IF EQUIPPED)
This feature is designed to greatly improve fuel economy. When
this switch is turned "On," the engine will only run at its normal
fast governed engine speed when electrical load is connected.
When the load is removed, the engine will run at a reduced speed.
With the switch "Off," the engine runs at the normal fast engine
speed all the time. Always have the switch OFF when starting and
stopping the engine (Figure 13).
2.5 VOLTAGE SELECTOR SWITCH (3.6 & 6.5KW
ONLY)
Allows the user to choose between 120/240 volts, or 120 volt
only. When in the 120 volt only position, the total generator output
is available through any of the 120 volt outlets. In the 120/240V
position, receptacles of 120 and 240 volts AC can be used
simultaneously. The voltage selector switch provides the user with
more usable power and improved flexibility.
NEVER switch the voltage selector switch with the main breaker
turned on! Doing this can cause arcing and can damage the
generator. First turn off all tools and appliances, turn off the
main circuit, and then operate the voltage selector switch.
2.6 HOW TO USE THE GENERATOR
If there are any problems operating the generator, please call the
generator helpline at 1-888-436-3722.
Never operate in an enclosed area or indoors! NEVER
use in the home, in a vehicle, or in partly enclosed areas
such as garages, even if doors and windows are open!
ONLY use outdoors and far from open windows, doors,
vents, and in an area that will not accumulate deadly
exhaust.
The engine exhaust fumes contain carbon monoxide,
which you cannot see or smell. This poisonous gas,
if breathed in sufficient concentrations, can cause
unconsciousness or even death.
NOTE:
Adequate, unobstructed flow of cooling and ventilating
air is critical to correct generator operation. Do not
alter the installation or permit even partial blockage of
ventilation provisions, as this can seriously affect safe
operation of the generator. The generator MUST be
operated outdoors.
This exhaust system must be properly maintained. Do
nothing that might render the exhaust system unsafe or
in noncompliance with any local codes and/or standards.
Always use a battery operated carbon monoxide alarm
indoors, installed according to the manufacturer's
instructions.
2.6.1 SYSTEM GROUND
The generator has a system ground that connects the generator
frame components to the ground terminals on the AC output
receptacles.
This generator system ground IS bonded to the neutral in the
generator (see applicable unit wiring diagram).
Special Requirements
There may be Federal or State Occupational Safety and Health
Administration (OSHA) regulations, local codes, or ordinances
that apply to the intended use of the generator. Please consult a
qualified electrician, electrical inspector, or the local agency having
jurisdiction:
• In some areas, generators are required to be registered with
local utility companies.
• If the generator is used at a construction site, there may be
additional regulations which must be observed.
Connecting to a Building's Electrical System through a
Transfer Switch
IMPORTANT: Connections for standby power to a building's
electrical system must be made by a qualified electrician. The
connection must isolate the generator power from utility power, or
other alternative power sources, and must comply with all related
laws and codes.
This generator system ground IS bonded to the neutral in the
generator (see applicable unit wiring diagram).
Operation
NOTE:
NOTE: