Gateway To Access Control Panel Connection - Schlage GWE Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Enter link mode for Schlage NDE-Series locks
1. Hold the interior lever.
2. While holding interior lever, apply a credential.
3. Wait until the lock begins to flash alternating
red and green, then release the interior lever.
It should take approximately 8 seconds to start
flashing after the credential presentation.
Enter link mode for Schlage Control locks
1. Present a credential.
2. Toggle deadbolt 5 times within 10 seconds of
card presentation.
Device Linking Responses
Link Mode
Success
Fail
If linking is unsuccessful:
1. Confirm that both devices have been
commissioned on the same ENGAGE site.
2. Move the Gateway 1 to 2 feet (30 to 60 cm)
in any convenient direction until all locks link
successfully. If still not successful, move the
Gateway closer to the locks and repeat the pre-
installation test, or add more Gateways.
WARNING
The lock will not show up in the Connect
screen of the ENGAGE mobile app after linking
to the Gateway. See below for instructions
for how to reconnect to your lock.
Reconnect to NDE-Series lock
Apply a credential while holding the interior lever
then immediately release the lever. Refreshing the
"Connect" screen in the app will allow the user to
connect to the lock. The lock will remain available
to connect for 30 seconds and then will resume
attempts to reconnect with the Gateway.
Reconnect to Schlage Control lock
Present a credential then toggle the deadbolt 5
8
Lights/Beeps
green flashes
4 beeps
4 red flashes
4 beeps
times within 10 seconds of card presentation.
Refreshing the "Connect" screen in the app will
allow the user to connect to the lock. The lock will
remain available to connect for 30 seconds and
then will resume attempts to reconnect with the
Gateway.
Device Linking Signal Quality
After a successful link with an ENGAGE Gateway,
some linked devices will give an indication of the
approximate wireless signal status received from
the Gateway:
Lights/Beeps
5 green flashes
4 amber flashes
3 red flashes
Gateway to Access Control Panel
Connection
CAUTION
Disconnect the Access Control Panel power and
batteries before wiring the Gateway to the panel.
WARNING
Because every Access Control Panel is
different, always check the panel's instruction
manual for appropriate interface wiring.
The EIA RS485 specification labels the data wires
as "A" and "B", however, many RS485 products
label their wires "+" and "-". Some products
associate the "+" signal with "A", some with "B".
Reversing polarity will not damage either RS485
device, it will just not communicate; if it does not
work, switch the connections.
The wires from the Access Control Panel must
be a shielded twisted pair.
For compliance with UL 294, product must
be used with a UL 294 Listed Access Control
Panel or unit, respectively.
Must be used with a UL 294 Listed power-
limited Power Supply capable of sourcing at
least 250mA @ 12 or 24 VDC.
Signal Strength
strong signal strength
medium signal strength
low signal strength