INITIAL SYSTEM SETUP
The.Aeromaster.12.allows.many.configuration.options.during.setup .
The.following.functions.can.be.configured.in.the.setup.mode:
.
•.Right,.Left,.Up.and.Down.Soft.Limit.Positions
.
•.Note:.Soft.limits.should.always.be.programmed.within.the.hard.travel.limits . . If.they.are.not.set.and.the.monitor.continuously.
.
hits.the.hard.travel.limits,.it.may.shorten.the.life.of.the.monitor . .
.
•.Monitor.Orientation.(sideways.or.inverted.mounting)
.
•.Position.Sensor."Zero"
.
•.Restore.Factory.Defaults
.
•.Obstacle.Avoidance
.
•.Stow.and.Deploy.Positions
To.enter.the.setup.mode.for.the.above.functions,.follow.these.steps:
.
1 . . Turn.power.off.to.Aeromaster.12
.
2 . . Press.and.HOLD.the.Stream.switch.(can.be.done.on.the.Joystick.or.the.Toggle.Switch.Box)
.
3 . . Turn.power.on.to.Aeromaster.12.while.continuing.to.hold.the.Stream.switch
.
4 . . Wait.3-4.seconds.and.release.the.Stream.switch
The.Aeromaster.12.should.now.be.in.setup.mode . . When.in.setup.mode,.the.LED.on.the.operator.station.and.the.lone.red.LED.on.the.
controller.housing.will.be.slowly.blinking.(a.short.blink.followed.by.a.long.pause) . . If.it.is.not.slowly.blinking,.turn.the.power.off.and.
repeat.steps.1-4 .
All.setup.functions.except.the.Stow.and.Deploy.Positions.can.be.scrolled.through.by.pressing.the.Stream.switch . . Each.time.the.
Stream.switch.is.pressed,.another.function.is.active.for.configuration . . If.a.function.is.configured.and.saved.using.the.Fog.switch,.the.
next.function.will.be.automatically.selected . . For.example,.the.first.time.the.Stream.switch.is.pressed,.the.Right.Soft.Limit.Position.
(LED.Code.1-1).is.ready.for.programming . . If.it.is.pressed.again,.the.Left.Soft.Limit.Position.(LED.Code.1-2).is.ready.for.programming . .
If.the.Left.Soft.Limit.Position.is.set.and.the.Fog.switch.is.pressed,.the.Up.Soft.Limit.Position.(LED.Code.1-3).will.be.automatically.
selected.without.having.to.press.Stream.again . . Alternatively,.activating.the.Stream.command.will.abort.this.function.without.
storing.the.position.and.the.next.function.will.be.selected . . Entering.the.Stow.and.Deploy.Positions.programming.modes.can.only.be.
accomplished.by.activating.the.Stow.or.Deploy.switch.while.at.the.start.of.the.setup.menu.(LED.Code.1.Slow.blink) . . (See.the.sections.
for.Stow.Position.and.Deploy.Position.for.more.detail) .
To.aid.in.determining.which.setup.menu.the.Aeromaster.12.is.in,.the.LED.on.the.operator.station.has.been.programmed.to.blink.a.
different.code.for.each.function . . The.table.below.lists.the.LED.codes.for.each.function . . The.codes.have.two.parts . . The.LED.code.will.
start.with.either.one.or.two.short.blinks,.a.short.pause,.another.series.of.short.blinks,.and.then.a.long.pause . . The.first.number.in.the.
LED.code.is.the.one.or.two.blinks.and.the.second.number.is.the.second.series.of.blinks.before.the.long.pause . . There.is.also.an.LED.
on.the.front.of.the.6052.Aeromaster.12.Controller.that.will.display.the.status.codes . . The.controller.is.mounted.at.the.base.of.the.
monitor .
Page.11