Restore Factory Defaults (Blink Code 1-9)
Occasionally,.it.may.be.desirable.to.return.to.factory.defaults . . To restore factory defaults when in this mode, press the fog switch.
This will clear all user selected settings and return to the start of the setup menu (LED Code 1 Slow blink). The.following.settings.
will.be.reset.to.factory.default:
•.All.soft.limit.positions.will.get.set.to.maximum .
•.Position.sensor."zero".values.will.return.to.the.values.set.at.the.factory .
•.Monitor.orientation.will.get.reset.to.standard.position .
•.Stow.and.Deploy.positions.are.reset.to.zero.degrees.as.established.at.the.factory .
•.Obstacle.Avoidance.profile.data.is.cleared.and.disabled .
It.is.possible.to.abort.this.mode.prior.to.activating.the.Fog.input.by.simply.removing.power.to.the.StreamMaster.II . . Alternatively,.
activating.the.Stream.command.will.abort.this.mode.without.restoring.factory.defaults.and.the.Obstacle.Avoidance.Disable.(Blink.
Code.2-1).mode.will.be.automatically.selected .
Obstacle Avoidance Disable (Blink Code 2-1)
Pressing the Fog switch will Disable Obstacle Avoidance, clear the Obstacle Avoidance Profile and return to the start of the
setup menu (LED Code 1 Slow blink). The factory default setting for obstacle avoidance is DISABLED. Alternatively,.activating.the.
Stream.command.will.abort.this.mode.without.disabling.obstacle.avoidance.and.the.Obstacle.Avoidance.Manual.Operation.mode.
will.be.automatically.selected .
Obstacle Avoidance Manual Operation (Blink Code 2-2)
Manual.operation.mode.requires.the.operator.to.manually.move.the.monitor.around.obstacles . . When.an.obstacle.is.encountered,.
movement.in.that.direction.stops.until.the.operator.moves.the.monitor.around.the.obstacle . . Pressing the Fog switch will select
Manual Operation for Obstacle Avoidance..Alternatively,.activating.the.Stream.command.will.abort.this.mode.without.selecting.
Manual.Operation.and.the.Obstacle.Avoidance.Auto.Operation.mode.will.be.automatically.selected .
Obstacle Avoidance Auto Operation (Blink Code 2-3)
Auto.operation.mode.does.not.require.the.operator.to.move.up.and.down.to.go.around.an.obstacle . . When.an.obstacle.is.
encountered,.movement.in.that.direction.stops.and.the.StreamMaster.II.automatically.navigates.up,.over,.and.back.down.around.
the.obstacle.as.long.as.the.joystick.is.maintained.in.the.horizontal.command.(right.or.left) . . Pressing the Fog switch will select Auto
Operation for Obstacle Avoidance..Alternatively,.activating.the.Stream.command.will.abort.this.mode.without.selecting.Auto.
Operation.and.the.Obstacle.Avoidance.Learn.mode.will.be.automatically.selected .
Page.14