Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 99
Network
Save
Back
NETMASK: Indicate the subnet mask (if different from the default setting).
GATEWAY: Should it be necessary to route data traffic towards other subnets, you can indicate a gateway in the relevant space.
Once all the necessary data have been entered, save the setting by pressing the button next to the
icon to access the list of options that can be set.
Sip
Save
Back

MAC ADDRESS

MODE
Static
IP ADDRESS
192.168.1.4
NETMASK
255.255.255.0
2nd April 2014
USERNAME
00401201002
PASSWORD
DISPLAY NAME
SERVER
192.168.1.3
Network
Note: to fill in the selected field, press the
button next to icon
and use the keyboard
that appears.
MAC ADDRESS: The Mac address of the
device cannot be changed
MODE: Lets you choose the type of address
from:
DHCP: The IP address of the device is as-
signed by the DHCP server.
Static: The IP address of the device is manu-
ally assigned
IP ADDRESS: If you have chosen to use a static
IP, enter the device's IP address in this space.
The address must belong to the same subnet as
the router and the other devices connected; the
default address is "192.168.1.4".
icon. Press the button next to
SIP
Note: to fill in the selected field, press the
button next to icon
and use the keyboard
that appears.
USERNAME: In this space enter the "SIP User
Name" assigned to the device by PCS Xip.
PASSWORD (absent by default): In this space
enter the password assigned in the Xip receiver
credentials in the server setup window.
DISPLAY NAME (option available only for sys-
tems without XIP Servers): In this space enter
the name that you want to give to the device.
SERVER: In this space enter the server's IP
address.
Default IP addresses of Bpt servers:
ETI/MiniSER Xip - 192.168.0.3 (port 0) -
192.168.1.3 (port 1)
ETI/SER Xip, 192.168.1.1

Publicidad

Tabla de contenido
loading

Tabla de contenido