Palazzetti ECOMONOBLOCCO WT 78F N Manual De Instalación Y Mantenimiento página 35

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

6.5
SAFETY DISTANCES FROM FLAMMABLE
MATERIALS
• In presence of flammable structures or other materials
behind or besides the furnace, the minimum distance
from them must be as per the attached table. (FIG. 6.1)
• All combustible materials that are located in the area
radiated by the heat from the glass of the door must be
placed at a distance of at least 180 cm from it.
6.6
EARTHING
ECOMONOBLOCCO WT 78 is provided with screw for
equipotential coupler that can receive a cable with cross-
section from 2.5 mm
the equipotential bonding of the earth in accordance with
the rules in force. This coupler is located in the rear part
of the ECOMONOBLOCCO WT 78 and indicated with
the symbol
(Fig. 6.2)
* For Italy these technicians must have the licence as per
letter "C" issued by the Chamber of Commerce according
to M.D. 37/08.
Also the flue system must be provided with its own earth
in accordance with local regulations.
FIG. 6.1
Z
Y2
X1
cod. 004777000 MBL - 19/12/2018 - Palazzetti - PN - Italy
to 6 mm
, that can be used to obtain
2
2
[cm]
X1
180
X2
10
Y1
70
Y2
70
Z
80
X2
Y1
A
B
FIG. 6.2 -
FIG. 6
C
D
E
G
H
35

Publicidad

Tabla de contenido
loading

Tabla de contenido