MAINTENANCE SCHEDULE
CLEANING FUEL STRAINER:
Dirt and water in the fuel are removed by the fuel strainer.
. Remove the strainer cup and throw away water and dirt.
(Fig. 20)
2. Clean the screen and strainer cup with gasoline.
3. Tightly fasten the cup to main body, making sure to avoid
fuel leak.
PERIODIC OPERATION AND INSPECTION:
When furnishing the generator as emergency electric power
source, periodic operation and inspection are needed.
Fuel (gasoline) and engine oil will be deteriorated with time,
and this causes the engine to be difficult to start and as
results improper engine operation and failure.
CAUTION: SINCE THE FUEL (GASOLINE) WILL
BE DETERIORATED WITH TIME,
REPLACE FUEL (GASOLINE) WITH
FRESH FUEL PERIODICALLY; ONCE
EVERY THREE (3) MONTHS IS
RECOMMENDED.
. Check the fuel (gasoline), engine oil and air cleaner.
2. Start engine.
3. With appliance such as lighting activated, run the engine
for over ten minutes.
4. Check the following items:
• Engine running properly.
• Adequate output and the indicator lamp turned on
properly.
• Then engine switch normally operated.
• No leakage of engine oil and fuel (gasoline).
Operator's Manual
Service
(Fig. 20)
37