The system operating parameters are set in the Intermediate menu. To access this menu, press the
buttons simultaneously for 5 seconds.
Access to the menu is password protected (see section 5.1).
The Intermediate programming menu contains the parameters shown in table 4 .
The parameters will be displayed one after the other. Press the button
the next.
While the parameters are being changed, the regeneration icon flashes.
All the changes made are saved when the message
programming processes are not therefore saved.
DATA
DESCRIPTION
E Enter password, to change the figure press the
key to move from one parameter to the next.
St: System Type:
Set 0 for Softening application, 1 for other kind of application
SH: Regeneration Mode:
- 0: Time clock regeneration on predefined days
- 1: Volumetric delayed regeneration
- 2: Volumetric immediate regeneration
- 3: Regeneration are initiated based upon a programmed time interval
(every 2, 3, 4, 6, 8 or 12 hours). The first generation starts at the
regeneration time set in the basic menu and following regeneration will
be carried out depending on the programmed interval.
- 4: Time clock regeneration
Unit of measurement.
Press buttons and to set the unit of measure (L=litres; M3 = cubic liter).
The option is displayed only if SH: 1 or SH: 2.
Interval between regenerations in hours. To change, use the
keys
The option is displayed only if SH: 3.
Inlet water hardness. Enter hardness of water at inlet.
To change press
or
.
The option is displayed only if SH: 1 or SH: 2 and St=0.
Outlet water hardness. Enter hardness of water at outlet of the system.
To change press
Make sure the mixing device is correctly set up
to match with the programmed value. In case the mixing device is
installed downstream the meter, set up this parameter to 0. Use the same
unit as the one used for the inlet hardness.
The option is displayed only if SH: 1 or SH: 2 and St=0.
Resin exchange capacity. Setting of resin exchange capacity expressed
in °f x m³ or °d x m³ per liter of resin. To set up the value, use
Use the same unit used for hardness.
The option is displayed only if SH: 1 or SH: 2 and St=0.
Page 17
to move from one parameter to
appears
Parameters changed during uncompleted
.
key. Press the
and
DEFAULT
MIN-
MAX
0000-
0000
9999
0
0-1
2(P1)
1(P2)
1-5
4(P3)
L
L-M3
12
2-12
20
1-999
0
0-999
5.0
0.1 - 10