Water Connections; Pump Speed Selection; Refrigerant Connections - Carrier 80AW1 Manual De Instalación

Ocultar thumbs Ver también para 80AW1:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 81
Installation

Water connections

Please refer to the Safety information manual.
When making the hydronic connections to the module,
always use a counter spanner when tightening.
To avoid bacteria and dirty proliferation in the circuit it is
recommended to use water treatment mixed water.
Place valves (not included) at the inlet and outlet of the
hydronic module.
Use pipe 1" or bigger for the connection between the
hydronic module and the fl oor / fan coil / radiator.

Pump speed selection

The pump provided with the module has 3 speeds.
The installer selects the speed of the module pump in order
to guarantee the target fl ow rate, knowing the available
pressure of the system at diff erent pump speed (see PSD)
and the pressure drop of the installation.
Hydronid
80AW1
module
CDU
38AW050 38AW065 38AW090
Nominal
Capacity
5,0
[kW]
Nominal DT
5
[°C]
Nominal
Flow Rate
860
[lt/h]
Min Flow
688
Rate [lt/h]
Max Flow
1032
Rate [lt/h]

Refrigerant connections

Please refer to the Safety information manual and the
R-410A- Installation manual.
WARNING :
The installer can rout the copper pipes from CDU to the
hydronic module. However the refrigerant connections
must be done by a skilled fridge installer during the
commissioning.
Before the commissioning the installer must rout the copper
insulated pipe from CDU to the hydronic module, cut it at
the correct length and close it at each side by pinching and
adhesive tape.
Make sure that during the routing, external materials do not
enter in the pipes.
80AW1-80AW2
20
Gb.indd 20
Gb.indd 20
80AW2
38AW115
6,5
9,0
11,5
5
5
5
1118
1548
1978
894
1238
1582
1342
1858
2374
Finally wrap connections with anti-condensate insulation
and tighten with tape, without exerting great pressure the
insulation.
When all the installation connections are complete, start
water fi lling.
For 80AW2 modules, the installer should also decide the
target fl ow rate for the zone, depending on the terminal
connected ; after that, the installer selects the speed of
the pump knowing the available pressure of the system
at diff erent speeds (see PSD) and the pressure drop of the
installation.
38AW050 38AW065 38AW090 38AW115
Max line length
w/o additional
20
refrigerant [m]
Min line lenght
1
[m]
Max height
diff erential
6
between ODU/
ID [m]
Refrigerant
R410A
1170
(standard<20m)
[g]
20
20
20
1
1
1
6
6
6
1360
2100
2100
1-01-1970 1:21:13
1-01-1970 1:21:13

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

80aw2

Tabla de contenido