OVERVIEW OF CHEMICALS ON WHICH THE HELMET HAS BEEN TESTED
Chemical
concentration (% by weight)
Sulphuric acid
30 (hydrous solution)
Sodium hydroxide
10 (hydrous solution)
p-Xylene
undiluted
Butane-1-ol
undiluted
n-Heptane
undiluted
OVERVIEW OF CHEMICALS ON WHICH THE VISOR HAS BEEN TESTED
Chemical
concentration (% by weight)
Sulphuric acid
30 (hydrous solution)
Sodium hydroxide
10 (hydrous solution)
p-Xylene
undiluted
Butane-1-ol
undiluted
n-Heptane
undiluted
IDENTIFICATION ON THE VISOR
EN 14458:2004
EN 14458:2004 Document number
CASCO
Manufacturer's name and identity mark
2015
Year of manufacture
+
Symbol for use by fire brigade (PF 112 EXTREME)
=
The icon for general use (PF 112 EXTREME)
K
Symbol for face protection
AT
Resistance to medium energy impact at extreme temperature
Electrical properties
i
Reference to user instructions
CE 0299
ID number of notified body
AFFIXING HOLLAND CLOTH
ALL-ROUND PROTECTION
This is achieved using the six snaps along the inner
edge of the helmet inner shell and temple area by
means of the pins along the interior construction.
14
AFFIXING NECK PROTECTOR
This is done by means
of the six press studs
along the helmet inner
shell. (Abb. 9, (see also
Fig. 2/13)).
Fig. 8
Fig. 9
MOUNTING THE FLASHLIGHT
As an option, a flashlight holder can be fitted to
each of the helmet adapters (right /left) (Fig. 10).
Fig. 10
TRANSMISSION FACTOR TO DIN EN 14458:2004
As can be seen from this illustration, the protection against radiated heat offered by this visor is dependant
on the temperature of the heat source. The visor should only be used in those situations where it can
reduce exposure of the wearer's eyes to less than 100 W/m².
Transmission factor 75% at 2400 K source temperature
100
90
80
70
60
50
40
30
20
10
500
1000
1500
REPLACEMENT OF PARTS
All the components in your helmet are designed for simplicity of replacement without the use of special
tools. The sweatband can be removed simply for cleaning or replacement. The supporting equipment can
likewise be replaced in its entirety by undoing the safety screws (Fig. 2/10). CASCO offers a variety of
accessories and spare parts for the PF 112 series, please contact CASCO for information regarding its
current selection.
FIRE FIGHTING HELMETS
Standard colours
PF 112 EXTREME noctilucent .................................................................................................... 8.112.11
PF 112 EXTREME day-glow ...................................................................................................... 8.112.13
Further colors / special colors upon request.
SPARE PARTS
- PU-Shell/ shock absorbing core ............................................................................................ 8.2014.03
- Holding system, including headring withturn-lock fastener, holding straps and leather ......... 8.2014.01
- Straps, including multi-functional accessory adapter,straps adjuster, Allen bolts ................... 8.2014.02
Further spare parts upon request. All spare parts are exclusively intended for use with CASCO PF 112
series helmets and have all undergone an EC type examination.
USE OF RESPIRATORY MASK
Please note that the interior construction is per-
fectly suited for use with a respiratory mask. There
is no need to order this separately. The angled form
of the head band allows the respiratory mask an
optimum fit within the helmet (Fig. 11).
Fig. 11
Transmission factor 9% at 586 K source temperature
Transmission factor,
low temperature
Transmission factor,
high temperature
2000
2500
15