MALFUNCTION
Weighing system does not operate.
Chain-driven unloading belt is seized.
Mixing takes longer than normal; the tractor works
too hard
Machine transmission is noisier than usual.
MALFUNCTIONS AND REMEDIES
– Check that pins are not rusted and wiring is not dama-
– Check that the inside of the belt is clean.
– Check that all drive system components (motor,
– Check (with the machine stopped and the cardan
– Check (with the machine stopped and the cardan
– Check that routine maintenance is performed as
– Check the oil level inside the reduction units as descri-
REMEDY
ged. Check the scales instruction booklet for malfunc-
tions.
chain, shafts, bearings ...) are in good condition.
shaft detached) that blades on the screw are sharp.
Replace them as described on page 107 if they are
not.
shaft detached from the tractor) that all components
subject to stress are lubricated as specified on page
106.
described on page 106.
bed on page 106.
108