3.1 Installation Preparation

3.1.1 Notice on Installation
(1) Notice on Refrigerant Concentration before Installation.
This air conditioner uses R32 refrigerant. The construction area for installation,
operation and storage of the air conditioner must be larger than the minimum
construction area. The minimum area for installation is determined by:
1) Refrigerant charging quantity for the entire system (ex-factory charging
quantity + additional charging quantity).
2) Checking out in the applicable tables:
a) For indoor unit, confirm the model of indoor unit and check the
corresponding table.
b) For outdoor unit that is installed or placed indoors, select the corresponding
table according to the height of the room.
Height of the room
<1.8m
≥1.8m
DC Inverter U-match Series Cassette Type Unit
Indoor Unit Accessories
Appearance
Outdoor Unit Accessories
Appearance
7
Q'ty
Usage
To prevent the
communication wire
from reaching out the
1
electric raceway(only
35/50)
Connect the panel and
4
body(only 35/50)
Q'ty
Usage
To plug the unused
1or3
drain hole
To connect with the hard
1
PVC drain pipe
Select the applicable table
Floor standing type
Wall mounted type