• Capacitance range of this meter: 6,6nF, 66,00nF, 660,0nF, 6,600μF, 66,00μF,
660,0μF, 6,600mF y 66mF.
To measure capacitance:
• Rotate rotary switch to
• Respectively connect black and red test probes to COM input socket and
input socket.
• Measure the capacitance value of circuit to be tested with other two ends of
test probes and read the measuring value from LCD display.
4.15 Frequency and duty ratio measurement
• Capacitance range of this meter: 60Hz, 600Hz, 6kHz, 60kHz, 600kHz,
6MHz, 60MHz.
To measure frequency:
• Rotate the switch to Hz position.
• Respectively connect black and red test probes to COM input socket and
Hz input socket.
• Measure the frequency to be measured with other two ends of test probes
and read the measuring value from LCD display.
4.16 Current measurement
• Current range of this meter: 660μA, 6600μA, 66,00mA, 660,0mA, 10,000A;
• Cut off the power supply of circuit to be tested. Discharge all high voltage
capacitors on the circuit to be tested.
• Rotate switch to the appropriate position (uA, mA or A grade).
• Connect the black test probe to the COM input socket. If the current to be
tested is lower than 600mA, connect the red test probe to the mA input
socket; if the measured current is between the range of 600mA~10A, the red
test probe should be connected to 10A input socket.
• Cut off the circuit to be tested. Connect the black test probe to one end of
disconnected circuit (low voltage, relatively), and connect the red test probe
to the other end of disconnected circuit (high voltage, relatively).
• Connect the power supply of circuit to be tested, then read the display read-
KPS-MT60 • Digital multimeter