Battery Replacement; Fuse Replacement - Klein Tools MM600 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

BATTERY REPLACEMENT

When
indicator is displayed on LCD, batteries must be replaced.
1. Remove screw from battery/fuse door.
2. Replace 2 x AAA batteries (note proper polarity).
3. Replace battery/fuse door and fasten securely with screw.

FUSE REPLACEMENT

A fuse may blow if more than 500mA is applied to the A/mA jack
or more than 10A is applied to the 10A jack
1. Remove screw from battery/fuse door.
2. Replace blown fuse(s) with:
A/mA jack
10A jack
3. Replace battery/fuse door and fasten securely with screw.
500mA/1000V fast-blow fuse
(Klein Cat. No. 69035)
To avoid risk of electric shock, disconnect leads from any voltage
source before removing battery/fuse door.
To avoid risk of electric shock, do not operate meter while
battery/fuse door is removed.
MAINTENANCE
: 500mA/1000V fast-blow (Klein Cat. No. 69035)
6
: 10A/1000V fast-blow (Klein Cat. No. 69034)
3
. To access fuses:
3
10A/1000V fast-blow fuse
(Klein Cat. No. 69034)
,
6
17

Publicidad

Tabla de contenido
loading

Tabla de contenido