- Adjust the closing force according codes using potentiometer CLOSE FORCE. The Closing Force will
increase by turning the potentiometer clockwise!
12.2 ADJUSTMENT OF THE SPEED
- The drive electronic offers to select one out of four different speed levels (for handicap elevators or other
purpose).
- Look at DIP-SWITCHES description (chapter 15).
12.3 SETTING SPEED ACCORDING TO DISABLED PEOPLE REGULATIONS
- The DIP-SWITCHES S1/5 and S1/6 must be set to OFF.
Sujeto a cambios sin previo aviso
DIP-SWITCHES S1/5 and S1/6 SET TO OFF
EXCELLENCE IN COMPONENTS