20.4.8 'F4': Next (Main Menu)
F1 Error List
F2 Belt Position
F3 Log Out
F4
This menu allows you to watch values described in the following chapters by pressing the corresponding
function key.
20.4.8.1
'F1 Error List'
Errors are coded with numbers or letters. The Error List can be deleted with the key 'F5' .
Possible Faults are:
'EC' : Fault by Encoder
'EE' : EEprom writing or reading fault
'OC': Over current
'RS' : Faulty reference switch
'IE' : Internal software fault
'AP' : Fault by positon counter, door width > 5m
'TS' : Faulty temperature sensor
'NE' : Encoder not connected
'CF' : Closing force potentiometer defect
'ME' : Fault by motor or encoder
'SS' : Standstill fault, door is blocked
'TH' : temperature of the electronic or motor too high
'FE' : is set during manual change of coupler movement parameter.
20.4.8.2
'F2 Belt Position'
Actual position of the belt, positive- door panels open (then it is the door panel position), negative - cou-
pler area
20.4.8.3
'F3 Log Out'
By pressing F3 the communication between door drive and WPT is stopped and the WITTUR Programming
Tool switches off.