15. DIP-SWITCHES
S1/1
Test Button operation (buttons active)
Automatic reopen on obstruction or IPD
S1/2
S1/3
Electric shoe operation (swing door mode)(*)
S1/4
S1/5
S1/6
S1/7
(open-and close force limitation active)
S1/8
(*) Mode 1:
I1 = ON -> door opens
I1 = OFF -> door clos-
es
Speed adjustment
ON
S1
1 2 3 4 5 6 7 8
Sujeto a cambios sin previo aviso
ON
(Reopen O3 is switched)
Speed selection, binary coded, see figure
Open force limitation active
Automatic end keeping
open
COM
door
I1
I2
I3
Ix
SPEED
MIN
1
2
3
OFF ON OFF ON
SP 0
OFF OFF ON ON
SP 1
Normal operation (command inputs on X1 active)
Normal operation (command inputs on X1 active)
Not used
(only close force limitation active)
Hold open/closed only on active open/close command
(*) Mode 2:
I1 = ON -> door closes
I1 = OFF -> door
opens
MAX
4
EXCELLENCE IN COMPONENTS
OFF
Activate SERVICE DRIVE SWITCH
No automatic reopen
(only Reopen O3 is switched)
No open force limitation
COM
I1
I2
I3
Ix
Subject to change without notice!
close
door