Lutron GRAFIK Eye GRX-CCO-8 Manual De Instrucciones página 5

Ocultar thumbs Ver también para GRAFIK Eye GRX-CCO-8:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 7
1
2
3
ON
Scene
Scene
Scene
1
2
3
4
5
1
2
3
OPTIONS
ON
Scene
Scene
Scene
1
2
3
4
5
5
6
7
OPTIONS
ON
Scene
Scene
Scene
1
2
3
4
5
9
10
11
OPTIONS
ON
Scene
Scene
Scene
1
2
3
4
5
13
14
15
OPTIONS
ON
Scene
Scene
Scene
1
2
3
1
2
3
4
5
OPTIONS
ON
Scene
Scene
Scene
5
6
7
1
2
3
4
5
OPTIONS
ON
Scene
Scene
Scene
9
10
11
1
2
3
4
5
OPTIONS
ON
Scene
Scene
Scene
13
14
15
1
2
3
4
5
OPTIONS
I
The GRX-CCO-8 may be set to either momentary or maintained outputs.
ON
Maintained. The appropriate GRX-CCO-8 output is closed as long as the corre-
sponding GRX Control Unit scene is selected.
1
2
3
4
5
OPTIONS
ON
Momentary. The appropriate GRX-CCO-8 output is closed for 1/2 second when the
corresponding GRX Control Unit scene is selected.
1
2
3
4
5
OPTIONS
I
Select how the GRX-CCO-8 will control its outputs. Refer to Assign GRX-CCO-8 to GRX Control
Units (Scene Control) for further details.
ON
All GRX Control Units to which the GRX-CCO-8 is assigned must be in the same
scene to close the corresponding output..
1
2
3
4
5
OPTIONS
ON
Any scene changes on any GRX Control Unit to which the GRX-CCO-8 is assigned
will close the corresponding output. The GRX-CCO-8 will activate the output asso-
1
2
3
4
5
OPTIONS
ciated with the most recent GRX Control Unit scene selection.
Outputs
4
5
6
7
Scene
Scene
Scene
Scene
4
5
6
7
Scene
Scene
Scene
Scene
8
9
10
11
Scene
Scene
Scene
Scene
12
13
14
15
Scene
Scene
Scene
Scene
16
1
2
3
Scene
Scene
Scene
Scene
4
5
6
7
Scene
Scene
Scene
Scene
8
9
10
11
Scene
Scene
Scene
Scene
12
13
14
15
Scene
Off
Scene
Scene
16
1
2
Set GRX-CCO-8 Address
8
The GRX-CCO-8 requires a unique address to operate properly with GRX Control Units. This is
Scene
accomplished by setting the ADDRESS Switches appropriately.
8
I
The GRX-CCO-8 occupies one of eight shade control addresses.
Scene
Address
12
ON
ON
1
2
1
2
3
4
5
Scene
ON
ON
16
5
6
1
2
3
4
5
Scene
Assign Outputs to Zones (Zone Control Only)
4
1. Set GRX Control Unit load types.
Off
I
For each output of the GRX-CCO-8 that is going to
control MWTs, set the load type on the desired zone
of the GRX Control Unit to AC Shades; refer to the
GRAFIK Eye Installer's Guide for more details.
Off
I
For each output of the GRX-CCO-8 that is going to
act as an individual output, the load type may be set
to any load type other than AC Shades or Sivoia
Off
Outputs are closed when the assigned zone intensity
is greater than zero.
2. Enter Programming Mode.
Scene
Press and hold the Program Button on the GRX-CCO-8 for about 3 seconds, until the Status LED
I
3
stops blinking and the Output Status LED(s) for the first Channel start to cycle (or blink if the
output is an individual output).
3. Assign MWT Channels or Individual Outputs to a GRAFIK Eye Zone
I
Press the ZONE Raise ( ) button on the desired zone of
the GRX Control Unit to which this output will be assigned.
The zone LEDs on the GRX Control Unit will be lit. (Press
the ZONE Lower ( ) button to unassign the selected out-
put). See diagram at right.
4. Select the next GRX-CCO-8 MWT Channel or Individual
Output
I
Press the GRX-CCO-8 Program button to select the next
output to be assigned. All LEDs for this Channel will start
cycling (or blink if the output is an individual output).
5. Assign the remaining GRX-CCO-8 MWT Channels or Individual Outputs
I
Repeat Steps 3 and 4 to assign the remaining GRX-CCO-8 channels or outputs.
5
ON
3
1
2
3
4
5
1
2
3
4
5
ON
7
1
2
3
4
5
1
2
3
4
5
.
4 5
1 2 3 4 5
NS
ADDRESS
ZONE 1
ZONE 2
GRX-CCO-8 Installation Instructions
ON
4
1
2
3
4
5
ON
8
1
2
3
4
5
Status LED
Program Button
Zone Label
FADE
TEMPORARY
Zone LEDs
00
ZONES
M S
Zone Raise/lower
MASTER
Buttons

Publicidad

Tabla de contenido
loading

Tabla de contenido