Slide the adapter of the mains connector in the battery pack fitting / adapter fitting until the battery
pack lock snaps tight.
•
Insert the plug of the mains connector into the appropriate power outlet.
5.5
CORE™ couplers
The hydraulic hose of the CORE™ system is a single hose, that combines a high pressure supply hose
inside a low pressure return hose. The female coupler has a unique function: after disconnection it
connects the supply and the return lines internally. This means you can connect and disconnect tools
without interrupting the oil supply to the hose.
5.6
Connect the hydraulic hose(s)
5.6.1
General
CAUTION
Never use damaged couplers.
Never use pliers or similar tools to connect the hydraulic couplers.
5.6.2
Hose with CORE™ couplers
Refer to Fig. 7.
•
Check the couplers for dirt and damage and clean them if necessary.
•
Insert the couplers by holding them against each other and pushing the male coupler with one
action into the female coupler. The external ring of the female coupler must move in the opposite
direction to the arrows.
•
Pull both couplers to check whether the couplers cannot be pulled apart with a normal manual
effort.
NOTICE
Do not store the hose with the ends coupled together.
5.7
Disconnect the hydraulic hose(s)
5.7.1
General
CAUTION
Never use pliers or similar tools to disconnect the hydraulic couplers.
5.7.2
Hose with CORE™ couplers
Refer to Fig. 8.
•
Disconnect the couplers by turning the external ring on the female coupler and then sliding it in the
direction of the arrows. The male coupler will slip out.
•
Remove dirt and oil from the couplers.
GBP10EVO3
916.400.220_001
EN