Best results and longest life of the battery pack are achieved when the battery pack is charged in a
dry environment at a temperature between 18 °C and 24 °C (64 °F and 75 °F).
CAUTION
The battery pack can be damaged if charged at a temperature below 0 °C or above 40 °C
(below 32 °F or above 104 °F).
The SOC indicator on the battery pack shows the state of charge of the battery pack.
The maximum capacity of the battery pack is achieved when it has been charged and discharged
some times.
Always charge the battery pack, also if it has been used for a short time.
The battery pack can stay connected to the battery charger for an indefinite period of time, because
it is protected against overcharging.
NOTICE
When the battery pack is not in use, it is advised to keep it connected to the battery charger
(connected to a power source) at all times. When the battery pack is full, the battery charger
automatically switches on and off at regular intervals to keep the battery level at 100%.
After deep discharge of the battery pack, charge the battery pack for 24 hours. If the battery
pack is not completely charged after 24 hours, contact your local Holmatro dealer.
5.12
Charging the battery in the docking station
Place the battery in the docking station. Make sure the battery snaps into the correct position.
Connect the charging cable between the battery charger and the battery charger connection on the
docking station.
Connect the power cable of the charger to the mains supply.
NOTICE
The battery will fully charge in approximately one hour.
NOTICE
After deep discharge of the battery, charge the battery for 24 hours. If the battery is not
completely charged after 24 hours contact your local Holmatro dealer.
5.13
LED battery level indicator
Refer to Fig. 2, 3.
The pump has a LED indicator that indicates the approximate battery level (the State Of Charge). The
battery should be charged before the red light on the battery level indicator starts blinking.
Indication SOC battery (State Of Charge):
/i
SOC
75% to 100%
50% to 75%
25% to 50%
1% to 25%
0%
GBP10EVO3
Indication on pump
3 green lights on
2 green lights on
1 green light on
1 red light on
1 red light blinks. A buzzer sounds. The pump stops.