OPERATOR TROUBLESHOOTING
PROBLEM
Fasteners will not drive completely into wood.
Fasteners penetrate properly during normal
operation, but won't drive fully at faster speeds.
Fasteners drive too deeply into wood.
Tools skips during operation - no fasteners are
driven from time to time.
Tool operates, but no fasteners are driven.
Air leaks at cap when tool is connected to air.
CAUTION
Disconnect the tool when performing
repairs or clearing jams.
14
CORRECTIVE ACTION
Increase air pressure (do not exceed 120 psi).
Increase air flow to tool -- use larger air lines
(3/8 inch ID minimum).
Reduce air pressure.
Make sure correct fasteners are being used.
Use fasteners that meet Duo-Fast
only.
Inspect check and feed claw for wear and proper
operation.
Clean as needed to remove debris.
Increase air flow to tool -- use larger air lines
(3/8 ID minimum).
Check magazine for proper fasteners. Fasteners
should slide freely with no follower pressure.
Increase air pressure (do not exceed 120psi).
Tighten capscrews.