5.2 Electrical Wiring

Check available power supply,
take note of pump name plate data requirements,
power wiring 3 x 1.5 mm". (Minimum cable size 6 mm, maximum 9 mm
OD).
To ensure water tightness and pull-force relief from the cable glands the
power
cable must be of sufficient outside diameter (e.g. 05 VV-F 3 (7) G 1,5
oder AVMH-I 3 (7) x 1,5).
All electrical wiring to be executed according to Fig.4.
Supply side fuse: see as for pump; maximum however 10 A, inert.
Strictly adhere to local earthing regulations.
If required (see VDE 0100), a ground fault circuit interruptor (GFCI)switch
must be provided and installed by others.
6
Commissioning
For possibly required prestart and commissioning procedures for the pump
refer to the separate installation and Operating Instruction for the pump.
Before initial start-up it must be ensured that sufficient suction capability is
available and that the pump is primed and filled.
On initial start-up the pump will run for 8 seconds, after that a renewed start-up
can be effected by keeping the reset button pushed.
7
Maintenance
16 (55)
All electrical site works to be carried out by qualified and
locally licenced electricians strictly in accordance with locally
ruling regulations.
Warning!
Electrical Shock Hazard!
Prior to maintenance or repair work turn off the pump and
ensure that it is not turned on by unauthorised personnel.