2. INSTALLATION
!
Warning
The product must only be installed by qualifi ed servicing and/or installation
personnel.
The electrical system must comply with current regulations in the country
where the product is installed.
Always make sure that the mains power supply is turned OFF before opening
the container. Ensure that there is a good earthing system. Always connect
it to the relative terminals.
2.1 PREPARATION
Before installing the device, prepare the tools required for securing it to the wall and to
make the electrical connections. The following are also required:
1. expansion wall plugs dia. 6 mm
2. Skintop type PG16 cable clamps
3. a multipole switch with a minimum contact opening of 3 mm
4. an emergency pushbutton
5. approved cables for external use with minimum cross-section of 0.75 and 1.5 mm²
2.2 ASSEMBLY
It is not necessary to drill any holes to fi t the device.
1. Secure the device at a minimum height of 30 cm, using the securing holes in
the plastic container.
2. Insert the connecting cables, through the holes in the bottom of the container
and the cable clamps indicated.
3. Fit a multipole switch upstream of the device.
4. Fit an emergency pushbutton in a position where the automation system can be seen
and so that the power supply to the system can be completely cut-off.
5. Use 1.5 mm² section cables for the motor power supply and 0.75 mm² section
cables for 24 VDC devices.
6. The device is not fi tted with peak capacitors; use the ones supplied
with the operators, or order the capacitors separately as indicated in the operator's
instructions.
2.3 ELECTRICAL CONNECTIONS
!
Warning
Make sure that the mains power supply is turned OFF before making the
connections.
The electrical system must comply with standards in the country where
it is installed. Use certifi ed materials. The system must only be installed
by skilled personnel.
Ensure that there is a good earthing system. Always connect it to the
relative terminals.
Do not use intercom or telephone cables.
Bundle the low tension cables (next to the K2 terminal board) and the power
cables (next to the K1 terminal board) securely together.
Make the electrical connections as indicated in the CONNECTION DIAGRAM.