Nordson iControl Prodigy Manual De Hardware página 81

Sistema de control integrado
Tabla de contenido

Publicidad

DC Discrete to/from GM1
DC Discrete to Booth Control Panel
NOTE: Refer to the following
manuals for additional
In/Out Positioner Panel
AC In (U)
PN 1055889 or
documentation and drawings:
Prodigy Powder Port: 1056625
PN 1070103 (reciprocator)
Prodigy Pump Panel: 1070518
Control Panel
Power Supply
Ethernet
FieldBus Controller
Reciprocator Speed
Controller
3ph In
Manual Gun
Controller 1
Powder Booth
CAN
24 VDC
Power Supply
One common Cable
CAN Out
6 meter limit
CAN In
Manual Gun
J−Box
PN 1057458
Run in one
common conduit
CAN
24 VDC
AC Discrete to/from FC
DC Discrete from FC
FD Box
AC In (U)
Manual Gun
pn 307445
Controller 2
Interlock
AC In (U)
In/Out Positioner Panel
3ph Out
PN 1055889 or
PN 1070103 (reciprocator)
3PH In (supply)
Control Panel
Power Supply
DC Discrete to/from FC
FieldBus Controller
Reciprocator Speed
3ph In
Controller
Power
Parallel Inputs (Discrete)
CAN Network
NOTE: You system may not have all
Ethernet Network
options shown here.
Fig. 7-1
Prodigy iControl System Diagram
E 2006 Nordson Corporation
FC Control Panel
PN1070692
Discrete
Pump Cab 3
Power Supply
Prodigy Powder Port
Feed Center
AC (S)
PS
Pump Cab 4
FC Network
J−Box
PN1070694
AC (S)
PS
AC Discrete from
FC Solenoid Panel
Booth Control Panel
PN 1070693
AC In
(S&U)
AC Out
(S&U)
AC Out (S)
AC J−Box (J−5)
AC In (S&U)
AC Out (U)
Network Interface Panel
PN 1057333
AC Adapter
Terminals:
Encoder Input
Vert. Zone Input
Part ID Inputs
Ethernet Switch
AC Out
Booth Control Panel
PN1070702
Booth I/O
Ethernet
Ethernet
Denotes: Ethernet Field Connection
Denotes: CAN Field Connection
Solenoid
Assembly
PN1070780
Pump Cab 1
Pump
Cab 3
AC (S)
PS
Pump
Pump Cab 2
Cab 4
AC (S)
PS
CAN Network Detail
AC Out (S&U)
CAN Out
CAN In
iControl Enclosure
AC In (U)
iControl
Ether
CAN,
I/O,
net,
PC104
PC104
PCI
CAN
Isolated
Input Interface
RIBBON
Gun 1−16 KV Cards
Gun Cables
Gun 17−32 KV Cards
CAN
Power Supply
AC In (S)
Parallel Inputs (25 conductor)
Ethernet
100 meter length Limit
Run in one
common conduit
Esquemas eléctricos y neumáticos
FC Network JBOX
Details
CAN Loop
Termination
CAN In
If Part ID services two iControl
systems, then AC power must be
Remote Part ID / Photoeye Stand
separately supplied.
AC In (U)
30 WATT PEJB,
PN 1035897
Power Supply
24 VDC
Terminals
;
Encoder Inputs
Vert. Zone Input
Part ID Inputs
GUNMOVER SCANNER
BOX, PN 1053590
Analog
Ethernet
Scanner
Controller
FieldBus Coupler
AC Adapter
Parallel Inputs (25 conductor)
Ethernet
Run in one
common conduit
7-3
Pump
Cab 2
Pump
Cab 1
Note:
AC Adapter, Ethernet
switch, and dashed line
wiring are 2nd Booth
optional components.
Ethernet and Discete Part
ID
to Booth #2
P/N 7135641A02

Publicidad

Tabla de contenido
loading