3. Top UV Lamp Replacement
a. Unplug the appliance from the wall outlet (picture 2.3-1).
b. Using a Phillips screwdriver, remove both screws from the back of the upper cover
(picture 2.3-2).
c. Remove the upper cover by pulling up and backwards.
e. Using a Phillips screwdriver, remove the four screws from the UV lamp cover (picture 2.3-3).
f. Remove the UV lamp cover, lift the used UV lamp out from the tank receptacle, then
disconnect from the pigtail socket by carefully pulling apart (picture 2.3-3).
g. Connect the new UV lamp with the pigtail socket by slowly pushing the four metal pins
into the top of the lamp.
h. Place the UV lamp back into the tank receptacle and screw UV lamp cover back into place.
i. Replace upper cover.
j. Reset flashing filter light (see "Resetting the flashing filter light," page 9).
2.3-1
Unplug from
wall outlet
Various countries, laws and regulations including, but not limited to, WEEE and RoHS,
****
require that all used electronic products (which includes ultraviolet lamps) must be
recycled/disposed of separately from normal household waste in order to optimize reuse
and recycling. ***
2.3-2
www.AtmosphericWaterSolutions.com
2.3-3
Remove the
two screws
located in the
back of the
upper cover
Remove the
screws and
cover
Take out the
UV lamp
11