Description Of Terminals; Pedestrian Gate Electric Lock Activation Time Setting; Speaker Sound Level Adjustment; Installation Completion - Urmet 1722/81 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
9.1.

DESCRIPTION OF TERMINALS

]
aP1
Hall button terminals for pedestrian electric lock (OP4)
]
aP2
Hall button terminals for garage gate lock (OP5)
}
c
Garage gate opener operation dry contact (OP6) - maximum switch 1 A @ 30 V
no
}
l
Bus line
l
}
se2
Pedestrian electric lock operation (OP1) - maximum switch 12 Vac 15 VA
se1
The position of jumper JP1 must not be varied.
9.2.

PEDESTRIAN GATE ELECTRIC LOCK ACTIVATION TIME SETTING

The pedestrian gate electric lock activation time can be adjusted using the dip switches present in the calling station:
9.3.

SPEAKER SOUND LEVEL ADJUSTMENT

Volumes are calibrated by default so not to require adjustments in most cases.
Use a screwdriver to adjust the speaker volume, if required.
9.4.

INSTALLATION COMPLETION

To complete the installation, close the panel using the metal lid and remove the protective films as shown in the following drawings.

JP1
do not change
the position
of this trimmer
A7
A4
DS17-06A

Publicidad

Tabla de contenido
loading

Tabla de contenido