Eu Declaration Of Conformity; Technical Data - EUCHNER CMS Serie Manual De Instrucciones

Cabezas de lectura/actuadores para unidades de evaluación
Ocultar thumbs Ver también para CMS Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operating Instructions
Red Heads/Actuators for Evaluation Units CMS

EU declaration of conformity

The declaration of conformity is part of the operating
instructions, and it is included as a separate sheet
with the unit.
The original EU declaration of conformity can also
be found at: www.euchner.com
Service
If service support is required, please contact:
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
70771 Leinfelden-Echterdingen
Service telephone:
+49 711 7597-500
Fax:
+49 711 753316
E-mail:
support@euchner.de
Internet:
www.euchner.com
CMS-R-A..-SC
CMS-M-A.
Connector assignment
View of connection side
2
4
3
1
Actuator
M8
5
The dimensions of the actuators are the
same as those of the read heads, although
the former have no plug connector.
Figure 2: Dimension drawings for read heads CMS-R-A..-SC / CMS-R-B..-SC
Dimension drawings for actuators CMS-M-A. / CMS-M-B.

Technical data

Parameter
Read heads
Housing material
Ambient temperature
Degree of prot.
acc. to EN 60529
Degree of contamination
(external, acc. to EN 60947-1)
Installation position
Connection
Switching voltage
Switching current I
e
Rated insulation voltage U
i
Rated impulse withstand
voltage U
imp
Method of operation
Mechanical life
Vibration resistance
Shock resistance
EMC compliance
Repeat accuracy R
Center offset m from actuator ± 2.5 mm at distance s = 3 mm
Switch-on distance s
ao
Switch-off distance s
ar
Switching contacts
Actuator
Housing material
Ambient temperature
Degree of prot.
acc. to EN 60529
Installation position
Method of operation
Vibration resistance
Shock resistance
Center offset m from read
head
Switch-on distance s
ao
Switch-off distance s
ar
87,5
67,5
7,2 ±0,25
Center offset m at s = 3 mm
2,5
2,5
Active face
5,5
78
±0,1
Design CMS-.-A...
Value
Fiber glass reinforced PPS
Approach
-20 ... +60 °C
direction
IP 67
2
Any, alignment with actuator
should be kept in mind (markings)
M8 plug connector
24 V DC
Min. 8 ... max. 500 mA
26.4 V DC
Design CMS-.-B...
1.5 kV
Magnetic, reed contact
100 x 10
operating cycles
6
10 ... 55 Hz, amplitude 1 mm
30 g/ 11 ms
According to EN 60947-5-3
≤ 10%
See combination options table
Fiber glass reinforced PPS
Design CMS-.-C... / CMS-.-E...
-20 ... +60 °C
IP 67
Any, alignment with read head
should be kept in mind (markings)
Magnetic
10 ... 55 Hz, amplitude 1 mm
30 g/ 11 ms
± 2.5 mm at distance s = 3 mm
See combination options table
Figure 1: Alignment of read head and actuator
CMS-R-B..-SC
CMS-M-B.
12,9
±0,25
5,7
Actuator
Center offset m at s = 3 mm
Active face
2,5
5
Alignment
marking
Y
X
Z
Alignment
marking
Y
X
Approach
direction
Z
Y
X
Approach
Alignment
direction
Z
marking
Connector assignment
View of connection side
8,5
2
1
4,5
2,5
M8
22
7
=
=
36
4
3