Display Messages - Delta SOLIVIA 2.5 EU G3 Manual De Operación Y Instalacion

Ocultar thumbs Ver también para SOLIVIA 2.5 EU G3:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 155
8.2

Display messages

DISPLAY
LED STATUS
MESSAGE
green: <on>
red: <on>
yellow: <on>
green: <off>
AC frequency
red: <off>
failure
yellow: <on>
green: <off>
AC voltage
red: <off>
failure
yellow: <on>
green: <off>
Autotest failed
red: <off>
(only for Italy)
yellow: <on>
green: <flashes>
Calibration
red: <off>
ongoing
yellow: <off>
green: <off>
DC injection
red: <off>
failure
yellow: <on>
green: <off>
red: <off>
Error # 301
yellow: <on>
green: <off>
red: <off>
Error # 302
yellow: <on>
green: <off>
Error # 506
red: <on>
Error # 508
yellow: <off>
Isolation start-
green: <on>
up warning
red: <on>
Isolation run-
yellow: <off>
ning warning
PV+ groun-
green: <on>
ding fault
red: <on>
PV- grounding
yellow: <off>
fault
green: <off>
red: <off>
Relay error
yellow: <on>
green: <off>
red: <off>
Revision error
yellow: <on>
28
CAUSE
Display communication
-
faulty.
Grid frequency overshoo-
ting or undershooting
specified limit range.
Grid voltage overshooting
or undershooting specified
limit range.
The autotest status is in
error.
Check internal settings.
DC component of input-
side alternating current is
too high.
Internal communication
error or hardware fault.
The device trips and
reverts to grid input mode
once the temperature has
dropped.
Isolation resistance fault
on the DC side during
start-up phase (# 508) or
running phase (# 506).
Isolation resistance fault
on the DC side during
start-up phase or running
phase.
Connection PV+ (PV-)
to GND is interrupted or
wrong pole is connected
to GND.
One of the anti-islanding
protection output relays is
faulty / defective.
Versions of hard- and soft-
ware are not compatible.
ELIMINATION
- If the fault persists after the device has
been reset, please inform your service
technician.
- Check the grid frequency via the display
in the N menu.
- Check the grid voltage via the display in
the N menu.
- If no voltage present, check grid auto-
matic circuit breaker.
Repeat the autotest routine.
Normal function before input mode.
- If the fault persists after the device has
been reset, please inform your service
technician.
- If the fault persists after the device has
been reset, please inform your service
technician.
- Check the installation site (no direct
sunlight, air circulation).
- Check the isolation resistance on the DC
side of the PV modules.
- You must check the isolation resistance
on the DC side of the PV modules.
Solar inverter is still feeding!
- Check that the GND connection has been
made correctly and/or check the fuse in
the grounding path. Change the fuse if
necessary. The solar inverter remains in
feed-in operation.
- The solar inverter is defective.
- Return the device.
- If the fault persists after the device has
been reset, please inform your service
technician.
Operation and installation manual SOLIVIA 2.5 EU G3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Solivia 3.3 eu g3

Tabla de contenido