Water Supply Requirements

IMPORTANT:
All installations must meet local plumbing code requirements.
There is not enough clearance to achieve a flush installation if
a water shutoff valve is located in the wall behind the
refrigerator.
The water shutoff should be located in the base cabinet on
either side of the refrigerator or some other easily accessible
area. The water supply line, however, must come up through
the floor in the gray shaded area shown.
6"
(15.2 cm)
A ½" (12.7 mm) hole for plumbing should be drilled on the
floor at least 6" (15.2 cm) from the right- or left-hand side
cabinet and should be no more than 1" (2.54 cm) away from
the back wall. See "Connect the Water Supply."
The water supply connection is made at the front of the
refrigerator.
If additional tubing is needed, use copper tubing and check
for leaks. Install the copper tubing only in areas where the
household temperatures will remain above freezing.
Do not use a piercing-type or ³⁄₁₆" (4.76 mm) saddle valve
which reduces water flow and also clogs more easily.
NOTE: Your refrigerator dealer has a kit available with a ¹⁄₄"
(6.35 mm) saddle-type shutoff valve, a union, and copper
tubing. Before purchasing, make sure a saddle-type valve
complies with your local plumbing codes.
Water Pressure
A cold water supply with water pressure between 30 and 120 psi
(207 and 827 kPa) is required to operate the water dispenser and
ice maker. If you have questions about your water pressure, call a
licensed, qualified plumber.
Reverse Osmosis Water Supply
IMPORTANT: The pressure of the water supply coming out of a
reverse osmosis system going to the water inlet valve of the
refrigerator needs to be between 30 and 120 psi (207 and
827 kPa).
If a reverse osmosis water filtration system is connected to your
cold water supply, the water pressure to the reverse osmosis
system needs to be a minimum of 40 to 60 psi (276 to 414 kPa).
If the water pressure to the reverse osmosis system is less than
40 to 60 psi (276 to 414 kPa):
Check to see whether the sediment filter in the reverse
osmosis system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill
after heavy usage.
If your refrigerator has a water filter, it may further reduce the
water pressure when used in conjunction with a reverse
osmosis system. Remove the water filter cartridge.
If you have questions about your water pressure, call a licensed,
qualified plumber.
10
6"
(15.2 cm)
1"
6"
(2.54 cm)
(15.2 cm)

Product Dimensions

IMPORTANT:
The depth from the front face of the doors to the back of the
refrigerator cabinet is 24" (60.96 cm) without panels.
The power cord is 84" (213 cm) long.
The water supply connection is made at the bottom front of
the refrigerator.
36" Single Door and 36" French Door Bottom Mount
Top View
24"
(61.0 cm)
Front View
Width dimensions were measured from hinge edge to clip
edge.
When leveling legs are fully extended to 1¹⁄₄" (3.2 cm) below
rollers, add 1¹⁄₄" (3.2 cm) to the height dimension.
35
(90.8 cm)
³⁄₄
35
"
(90.8 cm)
³⁄₄
"
83¹⁄₈"