TAB: 7509
3) Release the keys.
4) Press keys
and
simultaneously and hold them down (for
2 sec.) until the handset emits an audible signal and the entryphone
communicates with the entrance panel.
5) Release keys
and
.
Important: you have 5 s to press keys
step 4). If 5 s pass without pressing keys
in steps 1,2,3 must be repeated.
6) You now have 30 s to associate the ID code of the entrance panel:
- if using an alphanumeric entrance panel, enter the primary ID code
and confirm with the call key.
- in the case of a push button entrance panel, press the push button
you want to use to call the entryphone.
Important: when programming the primary and secondary ID, the entryph-
ones being programmed automatically acquire a code that depends on the
association with the push button or code used to call the entrance panel.
Correspondence between the primary ID and the respective secondary
ID codes is provided in the table below, in the wiring diagrams section.
Example: If ID = 8 is given to a second entryphone, the automatic second
entryphone identification attribution procedure will automatically assume
ID = 72 (see table).
When a call is made to ID = 8, both entryphones will ring and both can be
used to answer. If, on the other hand, you enter 72 (for alphanumeric pan-
els) which corresponds to the ID automatically assigned by the procedure,
the entryphone rings and it is possible to answer only from the entryphone
for which the secondary ID assignation procedure was carried out.
Important: to delete from a group, the programming deletion procedure
described in the "Default data restore procedure" paragraph must be used.
Push button programming
Important: without the SaveProg software, the only functions that can be
assigned are intercom calls, specific entrance panel auto-activation, re-
storing push buttons programmed by the installer to their default settings
and restoring default data.
Push button programming procedure for intercom calls
To programme the push buttons, proceed as follows:
1) Lift the handset of the entryphone to be programmed and hold to the
ear. (caller).
on the entryphone being programmed
2) Press keys
and
(caller) and hold down the two keys until the LED
3) Release keys
and
.
4) Press and hold down the push button to programme (for example ,
, , ).
5) Wait until the entryphone handset emits a continuous tone.
6) Release the push button to programme entryphone making the call.
7) Press a push button on the entryphone/video entryphone to call
(lock/F1/F2/Stair lights/Relay).
8) An audible signal in the handset of the (caller) entryphone being pro-
grammed confirms that the procedure has been completed correctly.
Procedure for restoring default data for each push but-
ton ( , , , )
1) Lift the handset and place to the ear.
2) Press the
and
keys simultaneously and keep them pressed
until the
LED starts flashing.
3) Release keys
and
.
4) Press and hold down the push button you want to return to default
programming (not valid for Self-start and Lock push buttons).
5) Wait until the entryphone handset emits an audible signal.
6) Release the push button.
7) Press the push button again to confirm. The entryphone handset will
Important: this procedure can be used to manually reprogramme all push
buttons with the exception of the lock and self-start push buttons, for which
the SaveProg software is required.
and
(as indicated in
Programming the self-activation/self-start push button
to a specific panel
and
, the procedure
(different from the self-start function enabled using push button
1) Lift the handset and place to the ear.
2) Press the
3) Release keys
4) Press and hold down the push button you want to programme (
5) Wait until the entryphone handset emits an audible signal.
6) Release the push button.
7) Call the entryphone from the panel you want to perform direct self-start
8) At the end of the procedure described above, the entryphone handset
Default data restore procedure
1) Lift the handset and place to the ear.
2) Press keys
3) Release keys
4) Press and hold down the key
5) When the entryphone handset emits an audible signal, during the signal
The entryphone programming has now been deleted. To check that pro-
gramming has been deleted, press push button
handset should emit an audible signal.
starts flashing.
EN
emit another audible signal. The push button has now been restored to
its default value.
and
keys simultaneously and keep them pressed
until the
LED starts flashing.
and
.
, , ).
:
from
- On push-button entrance panels, press the push button correspond-
ing to the entryphone on which the push button is being saved.
- On alphanumeric panels, enter the ID corresponding to the entry-
phone on which the push button is being saved and press the call
button on the panel to confirm.
emits an audible signal to indicate that the procedure has been com-
pleted correctly.
and
on the entryphone to programme (caller)
and hold the two keys down until the LED
and
.
release key
and press key
, ,
starts flashing.
again.
briefly.
; the entryphone
11
)