TAB: 7509
gramming the self-activation/self-start push button to a specific panel ").
Calling a concierge switchboard
To call a concierge switchboard (if installed in the system): lift the handset
and send the call by pressing key
Alert
Together with concierge switchboard 40510, the indoor station creates a
system that can send a signal to the switchboard operator even when the
Due Fili bus is busy. In contrast to other indoor stations, it is possible to
use only the pair of terminals FP-M as an input, not the keys. In this case
the local landing call function is lost. The FP-M operating mode is selected
using SaveProg.
1. Activate input FP-M. See below for the description of the two activation
possibilities.
2. The indoor station waits to receive the alert from the switchboard. In
the meantime, the chosen signalling is sent to the user according to the
table below. On receipt of the message, the switchboard emits a double
beep and displays a red envelope icon to alert the operator.
3. If it does not receive a replay, the internal station resends the message
every 10 s. After 5 attempts with no reply the indoor station stops send-
ing the messages.
4. When an indoor station receives confirmation of the receipt of the
message by the switchboard, the chosen signalling is sent to the user
according to the table below. Normally the time between the sending of
the request and confirmation of reception is less than a second.
5. Until the switchboard calls the indoor station to service the request, the
indoor station resends the message every 120 s. At each message,
the switchboard emits two meets and increases count of messages
received. The counter can be viewed by opening the list of alerts in
the switchboard. The sending of messages never terminates. It contin-
ues until the end of the service described in the next point, unless the
switchboard is powered off or removed from the system, in which case
the indoor station, after 5 unsuccessful attempts starting from the first
timeout of 120 s, will return to standby mode and the LED on the LOCK
key will stop flashing.
6. If the switchboard operator calls the indoor station from the list of warn-
ings, and only from this, a message is sent to the indoor station via the
Due Fili bus to end the Alert procedure so the relative signal is no longer
sent to the user.
Note: if the indoor station is switched off, when it is switched back on again
the function starts again from the beginning.
Alert Configuration
Use SaveProg to select some of the characteristics of the Alert function:
1. Enabling
a. Disabled (default)
b. Enabled
2. Polarity state active
a. Contact normally open (default)
b. Contact normally closed
3. Activation delay
a. 0.1 s (default)
b. 0.5 s
c. 1 s
d. 2 s
4. Signalling mode
a. None
b. LED
(default)
c. Sound
d. Call repeater output
According to the selected signalling type, apart from the first, the timer
is as follows:
STATE
LED timer
The indoor station waits
Flashing with a
to receive the alert from
cycle of 0.5 s on
the switchboard
/ 0.5 s off
The indoor station has
received confirmation of
Flashing with a
the receipt of the mes-
cycle of 0.1 s on
sage from the switch-
/ 0.1 s off
board
.
Sound timer
Call repeater
timer
Activation for
A 2 KHz tone
1.6 s every
for 0.2 s
3.2 s
Activation for
A 1 KHz tone
0.4 s every
for 0.1 s
0.8 s
Hearing aid function (Art. 7509/D only)
Art. 7509/D has an internal coil which allows hearing aid wearers to use
the device. In this operating mode, the hearing aid must be switched to
the "T" position. However, for correct operation of the hearing aid refer to
its instruction manual.
Note: any metal objects or electronic equipment nearby may compromise
the quality of the sound received by the hearing aid.