TAB: 7509
Signals:
F
In normal operation:
- Flashing light: indicates that the entryphone is receiving
a call (from an outdoor station or intercom device).
- Steady light: ringtone muted.
- Steady light with flashing (flashing 0.1 s, cycle 1 s):
indicates any lost calls. Even if the ringtone is ena-
bled.
During programming:
- Flashing light: indicates that programming is underway.
G
In normal operation:
- Steady light: door open indication, if the sensor is in-
stalled in at least one entrance panel and connected
between terminals PA and M.
During adjustment:
- Flashing light: indicates that the entryphone ringtone
volume is being adjusted or the melody selected.
Connection terminal block:
1, 2
Two pairs of terminals for Due Fili bus.
12V
Connection of additional ringtone (positive reference 12V).
CH
Connection of additional ringtone (repeat call) or "Alert" signal (see
relative paragraph).
FP
Input for landing call button (with reference to terminal M).
The maximum connection distance is 10 m.
With configuration using SaveProg, this input can be used for the
Alert function (see relative paragraph).
M
Earth reference.
Connection terminal block
Fig. 2
Bus termination for video signal stabilisation
The entryphone is provided with a connector A-B-C (OPEN-100-50) for
video signal stabilisation.
Depending on the connection configuration (entryphones/video entry sys-
tems connected in series or branched from a distributor), set a jumper on
the connector A-B-C (OPEN-100-50) as described in the note "Bus termi-
nation for ELVOX TWO-WIRE INSTALLATIONS" in the wiring diagrams
section below.
Bus termination
Fig. 3A
Installation
External surface mounting
- Install the entryphone away from light and heat sources.
- To open the entryphone lever off the cover with the fingers and if nec-
essary push a screwdriver into the two slots on the bottom of the entry-
phone to separate the cover from the base (Fig. 6).
- Fix the bottom of the entryphone (Fig. 5): directly to the wall using two
wall plugs or to a unified three-module rectangular flush mounting box
(Vimar V71303 type) installed vertically or to a round flush mounting box
(60 or 70 mm). Supplied as standard: 2 wall plugs for fixing directly to
the wall and two screws to use for fixing using the round mounting box.
- We recommend installing the entryphone with its lower edge at a height
of 1.40 m from the floor.
- Ensure that the wiring to the terminal block connected to the entryphone
base is done as shown in the wiring diagrams.
- Fit the entryphone cover: first position the top part and then push the
bottom part gently, until it clicks into place (Fig. 7).
Fig. 4
EN
A OPEN
B 100 Ω
C 50 Ω
Fig. 3B
1,40 m