Attaching and Removing the Adaptor
Removing adaptor plate
Lamp Test
Non-contact voltage detection is always on. When the probe or the antenna
is close to energized wires, LED flashes and beeps. Non-contact voltage
detection will be disabled when LAMP TEST button is pressed.
For better result, do the following while testing:
• Press and hold down LAMP TEST button for one second and release it
for one second.
• Operating time: one second ON, one second OFF for maximum five
cycles and wait for 1 minute before making another measurement.
Lamp Test with the Antenna
1. Attach the antenna to the test probe and make sure the switch is locked
and secured.
2. Pull the antenna to the desired length or fully extended.
3. Touch the surface of the light bulb with the tip of the antenna.
• To boost the test signal, install the adapter plate.
Do not touch the live parts with the antenna.
4. Press and hold down the LAMP TEST button
• The fluorescent lamp is good if lit during lamp test
• The fluorescent lamp is bad if not lit during lamp test
Attaching adaptor plate
Figure 3: Attaching and
removing the adaptor
7