Model 2500 / 2510 / 2520 / 2620
Model
Nominal output
Flue connection (diameter)
Weight
Recommended fuel
Fuel property, max. length wood
Electrical connection
Fuel
Mass flow of flue gasses
Temperature increase measured in the
measuring section
Temperature measured at appliance exit
Minimum draught
CO emission (13%O
)
2
NOx emission (13% O
2
CnHm emission (13%O
Particulate emission
Efficiency
24
2500
10 kW
150 mm
150 kg
Wood
50 cm
Wood
9.2 g/s
264 K
320 °C
14 Pa
0.10 %
)
52 mg/Nm³
)
21 mg/Nm³
2
16 mg/Nm³
80.0 %
2510
2520
10 kW
10 kW
150 mm
150 mm
180 kg
160 kg
Wood
Wood
50 cm
50 cm
230 V, 50 Hz, 0.5 A
Brown coal bri-
quettes
9.7 g/s
318 K
-
14 Pa
0.09 %
-
-
-
76.4 %
Subject to change because of technical improvements
2620
10 kW
150 mm
160 kg
Wood
50 cm
Anthracite coal
8.1 g/s
314 K
-
14 Pa
0.05 %
-
-
-
79.0 %