IND9D56 Installation Manual
With the brackets attached to the enclosure, use the assembly as a template to
mark the position of the mounting holes on the mounting surface.
Once the mounting hole positions are established, perform one of the following
procedures, depending on the type of wall surface.
Note:
WHEN CARRYING OUT THE FOLLOWING PROCEDURES, WEAR PROPER BODILY
PROTECTION, SUCH AS APPROVED SAFETY GOGGLES, EAR PROTECTORS AND GLOVES.
Wall Mounting, Concrete and Cement
Blocks
When mounting the IND9D56 to a cement block, poured concrete or similar wall,
the recommended mounting bolt is:
•
UL-listed concrete sleeve anchor, size 1/4" (6 mm), minimum embed 1/2"
(12.7 mm), minimum pullout force of 500 lb (266 kg).
Figure 2-2 shows an example of mounting hardware.
1. Drill a hole through each of the measurements/locations you marked in the
Preparation for Wall Mounting section. Use a carbide bit conforming to ANSI
B94, 12-77 with the same size bit as anchor diameter (typically 5/16" [8
mm]). The depth of the hole should be deeper than 1/2" (12 mm).
2. Clean the holes with a wire brush.
3. Make sure the head of the bolt is flush with the top threaded part of the anchor
then insert the anchor assembly through the mounting hole in the bracket and
into the base material.
4. Push anchor assembly until washer is snug against the wall.
5. Tighten each bolt with a wrench (use a screwdriver for flat/round heads),
approximately three or four full turns or until anchor is tightly secured to the
base material.
2-2
The hardware to mount the terminal to the vertical surface is not included
with the terminal – it must be supplied locally. Ensure that the mounting
hardware is capable of supporting the weight of the terminal, which is
approximately 40 lb (18 kg).
Figure 2-2: Sample Mounting Hardware, Concrete or Cement
CAUTION!