Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
3.9 x 13 screws
.
16
Note: with vertical applications, to prevent condensation
from forming inside the sensitive edge, using a Ø 4 mm
bit drill holes in the cap where the marking are, before
assembling it
.
17
Fitting the sensitive edge
Set up a corrugated tube (Ø 10 mm) required for the 
connection.
Place the fastening brackets at equal distances from the
center, mark and drill holes for fastening . Fasten the
brackets using wall plugs and Ø 4 mm  screws.
If necessary, as with metal structures, use self-threading
flared Ø 3.9 mm screws .
Drill a hole in the back of the aluminium rail and fit a cable
gland for the electric cable to pass through . With items:
DFW15/17/20 the hole is predrilled.
Use a probe to ease the cable passage in the rail .
Place the sensitive edge onto the brackets, drill the sides of
the edge using a Ø 2.5 mm bit  and fasten it using the UNI
6954 Ø 2.9x13 screws .
Make the required electrical connections depending on the
type of system (see Electrical Connections).
To adjust cable tension turn the adjustment screw on
the microswitch housing mechanism  and make sure
the microswitch is properly fitted: it must activate after
deforming by 20 mm max .
PROPER WORKING ORDER:
- starting position ;
- microswitch activation point (20 mm from the starting
position), reaction time = 0.2 seconds ;
- maximum crushing point = 45 mm from the starting point ;
- return to starting position time = 2 seconds .
Fasten the mechanism using the screw .
Fit the cap and fasten it using the UNI6954 Ø 3.9x13 bolts
and washers
.
11
11
11
1 1
-
ver.
01/2014
119RW83
119RW83
ELECTRICAL CONNECTIONS
Connecting to the control panel
Connecting to the control panel and control board (DFI)
Connecting to the Wireless module (RIOEDG01)
Connecting to the outdoor transmitter module (DBCT)
MAINTENANCE
☞ Before doing any maintenance, cut off the power supply,
to prevent any hazardous situations caused by accidentally
activating operator.
☞ The sensitive edge requires no special maintenance, but
it is better to periodically check (every six months) the state
of the rubber edge and working order of the device.
If necessary, clean the device using a vacuum cleaner or a
moist cloth (do not use either solvents or detergents).
Any modifications to the safety device, may result in a
hazard!

TROUBLESHOOTING

Problem
Possible cause
The edge does not
A cable is damaged
work
The sensitive edge
The microswitch
is slow in working
needs resetting
The operator does
The edge is engaged
not shut.
A cable is damaged
Declaration
device conforms to the essential, pertinent requirements provided by
directives 2006/42/CE and 2004/108/CE.
An original copy of the declaration of conformity is available on re-
quest.
Dismantling and disposal - Always make sure you comply with local
laws beforedismantling and disposing of the product. The packaging
materials (cardboard, plastic, and so on) should be disposed of as so-
lid urban waste, and simply separated from other waste for recycling.
Whereas other components (electronic boards, batteries, transmit-
ters and so on) may contain hazardous pollutants. These must the-
refore be disposed of by authorized, certifi ed professional services.
DO NOT DISPOSE OF IN NATURE!
The data and information in this manual may be changed at any time
and without notice.
Checks and fixes
Call for assistance
(stop using the
operator)
Call for assistance
Check that there are
no objects resting
against the edge or
that the edge is not
deformed (Call for
assistance).
- Came Cancelli Automatici S.p.A. declares that this

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Dfw15Dfw17Dfw20Dfw25

Tabla de contenido