7. TECHNICAL SPECIFICATIONS
Blue Smart IP67 Charger
Input voltage
Efficiency
Standby power consumption
Minimum battery voltage
Charge voltage 'absorption'
Charge voltage 'float'
Charge voltage 'storage'
Output current, normal mode
Output current, low current mode
Temperature compensation (lead-
acid batteries)
Charge algorithm
Can be used as power supply
Back current drain
Protection
DC fuse, internal and not replaceable
DC fuse in DC cable – ATO blade (A)
Operating temperature
Humidity (non condensing)
Start interrupt option (Si)
(12/25 and 24/12 models only)
Material & Colour
Battery-connection
230 V AC-connection
Protection category
Weight
Dimensions (h x w x d)
Safety
Emission
Immunity
28
12V 7/13/17/25A
93% / 93% / 95% / 95%
Starts charging from 0V (dead battery)
Normal: 14.4V
High: 14.7V
Li-ion: 14.2V
Normal: 13.8V
High: 13.8V
Li-ion: 13.5V
Normal: 13.2V
High: 13.2V
Li-ion: 13.5V
7 / 13 / 17 / 25A
2 / 4 / 6 / 10A
16mV/°C
6-stage adaptive
0.7Ah/month (1mA)
Reverse polarity (fuse), Output short circuit, Over
n.a / n.a. / 25 / 35 A
20 A (12/25: no fuse)
-30 to +50°C (full rated output up to 30°C)
Short cicuit proof, current limit 0.5A
Output voltage: max one volt lower than main output
ENCLOSURE
Aluminium (blue RAL 5012)
Black and red cable with M8 ring terminal 1.5 meter
12/7, 12/13, 24/5 - 12 AWG
12/17, 12/25, 24/8, 24/12 - 9 AWG
Cable of 1.5 meter with
CEE 7/7, BS 1363 plug (UK) or AS/NZS 3112 plug
12/7, 12/13, 24/5: 1.8kg
12/17, 12/25, 24/8, 24/12: 2.4kg
12/7, 12/13, 24/5: 85 x 211 x 60 mm
12/17, 12/25, 24/8, 24/12: 99 x 219 x 65 mm
STANDARDS
EN 60335-1, EN 60335-2-29
EN 55014-1, EN 61000-6-3, EN 61000-3-2
EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
24V 5/8/12A
230VAC
94% / 96% / 96%
0.5W
Normal: 28.8V
High: 29.4V
Li-ion: 28,4V
Normal: 27.6V
High: 27.6V
Li-ion: 27.0V
Normal: 26.4V
High: 26.4V
Li-ion: 27.0V
5 / 8 / 12A
2 / 3 / 4A
32mV/°C
Yes
temperature
n.a. / 15 / 20 A
20 / 10 / 15 A
Max 95%
IP67