TUBE REPLACEMENT
D
E
INSTALL NEW TUBE
1. To install new tube, insert one fitting into slot, pull tube around the center of the roller
assembly and insert second fitting into the other slot. Illustration D
2. Align tube housing cover with track and slide over tube until fully closed. Illustration E
3. Plug the pump in.
4. Run the pump for one minute to relax the tube. Press the
pump to ON. When pump is set to ON, it will run continuously and bypass any
programmed timers. To stop the pump from running in
programmed timers, press the
remain off until the operating mode is changed to ON or AUTO.
5. To lock cover in place, press down on the cover while turning the vertical tab 180
degrees from right to left. Install the Phillips head locking screw (CE models only).
Illustration F
6. Run the pump for one minute to verify operation.
7. Reconnect the suction and discharge lines.
8. Prime the pump and then set it to the desired operating mode.
F
MANUAL
USA and Canada 800.683.2378, International 904.641.1666
continued
MANUAL
MANUAL
button to set the pump to OFF. The pump will
button to set the
or from running the