FES-200 W3
1
Place the cover on the fume extraction
system
Fig. 5
Changing the filter
Proceed as follows:
Fig. 2 Functional description on page EN-11
1 Put the fume extraction system on the floor.
2 Switch off the fume extraction system by turning the rocker switch (11) (0 position).
3 After having switched off the fume extraction system, wait (for approx. 1 minute) until the dust has settled down in the
fume extraction system.
4 Unscrew the mounting screws (3) from the cover and lift it off.
5 Place the cover carefully on the fume extraction system so that the filter cartridge points upwards.
6 Press the rotation mechanism carefully downwards.
7 Place the dust collecting bag completely over the filter cartridge (5) and pull it down to the cover.
8 Loosen the filter cartridge (5) by turning it to the left (counter-clockwise direction).
4
Closing the dust collecting bag tightly
Fig. 6
Removing the filter cartridge
9 Remove the filter cartridge (5) and slide it completely into the dust collecting bag.
10Close the dust collecting bag tightly.
11 Clean the sealing surface of the cover using a damp disposable cloth.
12 Dispose of the dust collecting bag and the disposable cloth according to the local regulations.
12 Disposal on page EN-24
BAL.0335.0 • 2019-08-16
2
Pull the dust collecting bag over
the filter cartridge
5
Inserting a new filter cartridge into the
locking mechanism
5 Functional description
3
Loosen the filter cartridge
6
Checking the locking points
EN - 15