Figure 15 - Battery Connections
RED (+)
BLACK(-)
3.5 SERVICE AIRFILTER
The engine will not run properly and may be damaged if using a
dirty air filter. Clean the air filter every 50 hours or once a year
(Figure 16). Clean or replace more often if operating under dusty
conditions. The air filter part numberis 0G84420151.
1. Removeair filter cover.
2. Wash in soapy water.Squeezefilter dry in clean cloth (DONOT
TWIST).
3. Cleanair filter cover before re-installingit.
NOTE:
To order a new air filter, please contactthe nearest authorized
service centerat 1-888-436-3722.
Figure 15- Air Filter
KNOB TO OPENAIR BOX
3.5.1 CLEAN SPARK ARRESTOR SCREEN (CARB
MODELS)_
The engine exhaust muffler has a spark arrestor screen. Inspect
and cleanthe screen at least once each year (Figure17). If unit is
used regularly,inspect and clean more often.
i/_lf
using the generator on any forest=covered,
brush=covered
or grass=covered unimproved
land, it must equipped with a spark arrestor.
The spark arrestor must be maintained in good
condition by the owner/operator.
Cleanand inspectthe spark arrestor when the engine is at ambient
temperatureas follows:
1. Remove the spark arrestor screen from the muffler by
looseningthe clamp and removing the screw.
2. Inspect screen and replace if torn, perforated or otherwise
damaged. DO NOT USEa defective screen. If screen is not
damaged,clean it with commercial solvent.
3. Replace the spark arrestor and secure with the clamp and
screw.
Figure 17 - Spark Arrestor Screen
Spark
Arrestor "-_/
Cone
i
Spark
_/Arrestor
_
Screen
C,a,.p
NOTE:
Toorder a new air filter or sparkarrestor screen,pleasecontact
the nearest authorizedservice center at 1-800-333-1322.
3.6 VALVE CLEARANCE
• Intake-- 0.15 _ O.02mm (cold), (0.006" _ 0.0008" inches)
• Exhaust-- 0.20 _ O.02mm (cold) (0.008" _ 0.0008" inches)
After the first 50 hoursof operation, checkthe valve clearance
in the engine and adjust if necessary.
Important: If feeling uncomfortable about doing this procedureor
the proper tools are not available, pleasetake the generatorto the
nearestservice centerto havethe valve clearanceadjusted.This is
a very important step to ensurelongest life for the engine.