Enerpac B Serie Hoja De Instrucciones página 2

Bombas electricas portatile de 0,37kw
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
SPECIFICATIONS
Operating Pressure
Electrical Power Source
Motor Rating
Flow Rate
Max. Operating Temperature
Model No.
Used with Cylinder
PUD-1100B
PUD-1101B
Single-acting
PUJ-1200B
PUJ-1201B
PUJ-1400B
Double-acting
PUJ-1401B
Dimensions in. [cm]
Models
PUD-1100B/E, PUJ-1200B/E, PUJ1400B/E
PUD-1101B/E, PUJ-1201B/E, PUJ1401B/E
* The "D" dimension on the PUJ-1400B/E is 6.18 in. [15,7 cm]; on the PUJ-1401B/E, it is 6.58 in. [16,7 cm].
INSTALLATION
Hydraulic Connections
"B" Models
15 Amp 120 V. grounded 1 Ph. 50/60 Hz
1
/
HP Universal, 9 Amps at 10,000 psi
2
(700 bar) & 12,000 RPM operates at
60-125 Volts 85-89 dBA
200 in.
Valve Type
Dump Valve
3-Way, 2-Position
4-Way, 3-Position
D
G
B
A
9.62
(24,43)
12.18
(30,94)
1
Use 1
/
wraps of teflon tape (or suitable thread sealant) on all threads, leaving the first complete
2
thread free of tape to ensure that the tape does not shed into the hydraulic system, causing
damage. Trim loose ends.
WARNING
To ensure proper operation, avoid kinking or tightly bending hoses. If a
hose becomes kinked or otherwise damaged, it must be replaced.
Damaged hoses may rupture at high pressure, causing personal injury.
0 - 10,000 psi [700 bar]
.37 kW Universal, 4 Amps at 10,000psi
3
/min. (3,3 l/min) at 0 psi (bar) to 200 psi (14 bar)
3
20 in.
/min. (0,33 l/min) at 10,000 psi (700 bar)
150°F (65°C)
Usable Oil Capacity
3
122 in.
3
231 in.
3
122 in.
3
231 in.
3
122 in.
3
231 in.
C
F
E
Figure 1
B
C
D
9.62
14.25
4.72
(24,43)
(36,20)
(11,99)
14.50
14.72
5.12
(36,83)
(10,54)
(13,00)
2
"E" Models
10 Amp 220 V. 1 Ph. 50/60 Hz
(700 bar) & 12,000 RPM 85-89 dBA
Weight
31 lbs.
43 lbs.
27 lbs.
39 lbs.
32 lbs.
44 lbs.
A
E
F
G
5.25
4.00
8.12
(13,34)
(10,16)
(20,62)
5.62
4.15
12.77
(14,27)
(10,54)
(32,43)
H
0.75
(1,90)
0.62
(1,57)

Publicidad

Tabla de contenido
loading

Tabla de contenido