ENGLISH
PREFACE
Using this manual
This manual is intended to be used as a work of reference for
professional, well trained and authorised users to be able to
safely install, use, maintain and repair the product mentioned
on the cover of this document.
Pictograms and symbols
The following pictograms and symbols are used in this manual:
TIP
Suggestions and recommendations to simplify
carrying out tasks and actions.
CAUTION!
Procedures, if not carried out with the necessary
caution, could damage the product, the workshop or
the environment.
WARNING
Procedures which, if not carried out with the necessary
caution, may damage the product or cause serious
personal injury.
WARNING
Denotes risk of electric shock.
WARNING
Fire hazard! Important warning to prevent fire.
Text indicators
Listings indicated by "-" (hyphen) concern enumerations.
Listings indicated by "•" (bullet point) describe steps to perform.
Service and technical support
For information about specific adjustments, maintenance or
repair jobs which are not dealt with in this manual, please
contact the supplier of the product. He will always be willing to
help you. Make sure you have the following specifications at
hand:
- product name
- serial number
These data can be found on the identification plate.
1
INTRODUCTION
1.1
Identification of the product
The product consists of various components, the identification
plates of which contain the following data:
- product name
- serial number
- supply voltage and frequency
- power consumption
1.2
General description
The EDS is a free-standing general filtration system that
prevents accumulation of welding fume by continuous filtration
of polluted air. It consists of a central filter unit, a fan in sound-
absorbing case, an outlet unit with adjustable outlet nozzles, a
silencer and a control panel with frequency inverter and PLC.
1.3
Options and accessories
There are no options and/or accessories available for this
product.
0507340050/010111/D EDS
1.4
Technical specifications
Filter material
Filter surface area
Filter class (according to DIN EN
60335-2-69)
Required compressed air quality
Required pressure
Compressed air connection
Compressed air consumption
Duration offline cleaning cycle
Unrestricted airflow
Power consumption fan
Connection voltage
Insulation class fan
Nominal current
Protection class
Weight (net)
Refer to the available product data sheet for detailed
product specifications.
1.5
Dimensions
Refer to Fig. I on page 74.
1.6
Ambient conditions
Min. operating temperature
Nom. operating temperature
Max. operating temperature
Max. relative humidity
2
PRODUCT DESCRIPTION
2.1
Components
The system consists of the following main components and
elements:
Fig. 2.1
A
outlet unit with 6 adjustable nozzles
B
duct Ø 500 mm (19.7 in.)
C
silencer
D fan in sound absorbing case
E
control panel
F
fan frame
G adjusting feet (8x)
H control box + pressure reducing valve
I
drum
J
filter base frame
K
filter base
L
air inlet module
M filter cartridges
N RoboCleanPlus automatic filter cleaning system
cellulose fibres provided
with precoat
2
2
2 x 75 m
(2 x 807 ft
)
L
dry and oil-free
according to ISO 8573-3
class 6
6 bar (90 psi)
quick connect coupling Ø
9 mm (CEJN 320)
max. 150 nl/min. (5.3
3
ft
/min.) (depending on
the degree of saturation
of the filter)
90 minutes
3
max. 12.000 m
/h
(7063 CFM)
7.5 kW (10 HP)
380-480V/3~/50-60Hz
F with PTC
13.9 A
IP 54
800 kg (1764 lbs)
5°C (41°F)
20°C (68°F)
45°C (113°F)
80%