FWECK
The LCD controller can be installed directly (on both
provided, which contains:
Remote air temperature sensor (cable length 1.5 m)
Support for installation on the indoor unit
Frame
Sensor holder trap and clamp
Before to install the controller remove the
transparent coatingon the display with care;
the removal can produce the presence of dark
spots on the display that will disappear after a
few seconds.
I
NSTALLATION ON THE SUPPORT AND FAN COIL
UNIT
1.
take off the fan coil unit cabinet. (Fig. 1)
2.
Open the controller after removing the screw of the
cover; pass the cables through the rear slot and wire
them to the connectors as indicated in the diagram.
Plug in the connectors and close the controller again
(Fig. 2).
3.
Remove the precut plastic tabs from one of the
two windows so as to match up with the slot on
the rear of the controller which will be used for the
electrical wiring of the support (Fig. 3) (one or the
other window of the support depending on whether
the controller will be mounted on the left or right side
of the fan coil unit).(Fig. 3) A=Support B=Blank tabs
4.
Pass the cables through the slot in the support and
fasten the support and controller together using
the two screws provided. (Fig. 4 Controller support
fastening shows how the controller and support
should be assembled if the controller is installed
on the right side of the fan coil unit: if the controller
is installed on the left side of the fan coil unit, the
support will have to be turned by 180°).
5.
Make the electrical connections according to the
diagrams provided in controller manual (remove
valve and heater cables where these devices are
not present).
6.
Once the electrical connections have been made,
before completing installation of the controller it
Installation and operation manual
1
Kit installation on board
is recommended to carry out the self-diagnosis
procedure to check whether all outputs are
functioning correctly (fan at the different speeds and
valves where present): refer to the relevant section
in controller manual.
7.
Fit the controller-support assembly to the fan coil
unit using the bayonet couplings (Fig. 5)
8.
Warning: position the air temperature sensor (black)
and water sensor (white) following the directions
provided, for water sensor, in temperature sensor
kit manual
9.
Set the cabinet back on top of the fan coil unit,
covering frame in place as shown in Fig. 6 Mounting
the frame on Estro
T
EMPERATURE SENSOR INSTALLATION
The temperature sensor is included in the installation kit
and is necessary only for the installation of the controller
on the unit.
I
NSTRUCTIONS FOR INSTALLATION
Fig. 7 Fan coil unit without mount
Fig. 8 Fan coil unit with mount
Fig. 9 FWL fan coil unit with front intake
Use the adhesive sensor holder provided
FC66002766
To
prevent
disturbance
malfunctions, make sure that the sensor cables
are NOT situated in proximity to power lines
In case of prolongations use shielded cable
only; the shielding should be connected to the
ground on the lcd control side only.
Installation and
operation manual
and
consequent
(
7-8-9):
FIG
FWECK
Kit installation on board

Publicidad

Tabla de contenido
loading