Roof Anchor Type P (Pantile) - Vaillant auroTHERM VFK 125 Manual De Instrucciones

Ocultar thumbs Ver también para auroTHERM VFK 125:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6.2.1

Roof anchor type P (pantile)

1
3
Fig. 6.3 Roof anchor type P
Key
1 Lower roof anchor
2 Upper roof anchor
3 Centre roof anchor
The roof anchor type P can be fixed to the rafters
(Pos. A) or to the roof batten (Pos. B).
Fixing to rafters
2
1
Fig. 6.4 Fixing to rafters
1. Uncover the rafters where needed. For distances
please see Tab. 6.2 and 6.3.
2. Position the roof anchor. Pay attention to the correct
position of the upper and lower roof anchor (see Fig.
6.3).
3. Loosen the upper bolt with the socket/combination
wrench (SW 13) until the height of the roof anchor can
be adjusted.
4. Position the roof anchor at the same height of the
pantiles, so that the upper part of the anchor is on the
roofing, and tighten the bolt with the socket/combina-
tion wrench (SW 13).
5. Screw the roof anchor to the rafters with the 3 sup-
plied bolts.
Installation manual auroTHERM 0020057143_04
2
3
4
B
5
6. Slide the pantiles back to the original position.
If necessary, adapt the water gutter on the lower (A)
or upper side (B) of the pantile with a hammer, until
the pantiles are tight.
h
Note
With some types of roof it may be necessary to
move the roof anchor to the side with respect
to the rafters.
Use the „long lower section" accessory, Part
No. 0020080177 (not available in all coun-
tries).
Observe the associated assembly instructions.
On-roof mounting 6
2
1
A
6
B
GB
A
19

Publicidad

Tabla de contenido
loading

Tabla de contenido