Lock/Unlock Button
The pump has a 5-minute auto-lock. The LED light will dim out when
the pump is locked (no function is activated).To lock or unlock the
pump, place a finger over the lock/unlock button for 3 seconds.
Lay-Z-Massage System Button
Use this button to activate the massage system, which has a 30-minute
auto-shutoff feature.
The light above the Massage system button displays red when activated.
IMPORTANT: Do not run the Massage system when the
cover is attached. Air can accumulate inside the spa and
cause irreparable damage to the cover and bodily harm.
NOTE: Heat and massage system work together to
create a warm massage experience.
HydroJet System Button
This button turns the water pump on and off.
The light above the HydroJet system button displays red when activated.
Note: The system will shut off automatically after 1 hour.
Note: Do not dry run the HydroJet System.
Heat Button
Use this button to activate the heating system. When the light above the heat
button is red, the heating system is activated. When the light is green, the water
is at the set temperature and the heating system is at rest.
NOTE: If the heating system is activated, the filtration system will automatically start.
NOTE: After turning off the heating system, the filtration system will continue to operate.
Water Filter Button
This button turns the filter pump on and off.
The light above the Water Filter Button displays red when activated.
NOTE: The built-in hard water treatment function works automatically.
Power-Saving Timer Button
This is a newly added function, designed to help avoid wasting power by
setting the time and duration of the heating cycle for the spa.
This way, you can enjoy your spa at the time you desire, without needing to
leave the heater on at all times.
STEP 1: Set the heating duration
1. Press the
button unit the
2. Press the
or
button to adjust the heating duration (From 1-48 hours).
3. Press the
button again to confirm the heating duration.
STEP 2: Set the number of hours FROM NOW when the heater will activate
1. After setting the heating duration, the
2. Press the
or
button to adjust the hours until time of activation (From 0-99 hours).
3. Press
button again or simply touch nothing for 10 seconds to confirm the setting.The
LED will light steadily, and the countdown to heater activation will begin.
To modify the timer settings: Press the
adjust.
Cancel the setting: Press the
button for 2 seconds.
NOTE: After setting, the screen flashes the current temperature and time alternately.
NOTE: Timer adjustment (amount of time with the heater ON) may be set from 1 to 48 hours;
Reservation time adjustment (the number of hours FROM NOW when the heater will begin
to function) may be set from 0 to 99 hours. If the timer is set at 0 hour, it means the Timer
function is not set.
Alarms
Causes
The water flow sensors work
without pressing the filter or heat
button.
After starting or during the
functions of filtering or/and
heating, the water flow sensors
do not detect water flow.
The pump's thermometer reads
the water temperature below
4°C (40°F).
The pump's thermometer
reads the water temperature
over 48°C (119°F).
The pump's thermometer
connections have issues.
The thermal cut-out cut off.
104°C (219°F) Fuse fault.
Signal line disconnected.
MAINTENANCE
NOTE: Your spa will require additional air to be added from time to time. Changes
in temperature from day to night will change the pressure in the spa and may
cause a certain amount of deflation. Please follow the Assembly instructions and
drain the spa before inflating to the accurate pressure needed.
CAUTION: YOU MUST ENSURE THE PUMP IS UNPLUGGED BEFORE BEGINNING
SPA MAINTENANCE.
303021212340_14x21cm_54139;54296_20季美规HydroJet SPA说明书_英
LED starts to flash.
LED starts to flash.
button and use the
or
button to
Reasons
1. The water flow sensor flags didn't fall back into the
correct position.
2. The water flow sensors are broken.
1. You forgot to remove the 2 stopper caps from inside
the pool.
2. The filter cartridges are dirty.
3. Activate the filter or heat system and put your hand
in front of the outlet pipe inside the pool to check if
you can feel water. flowing out.
a. If no water flows out the water pump is broken.
b. Water flows out but the alarm
water flow sensors are broken.
1. The water temperature is lower than 4°C (40°F).
2. If the water temperature is higher than
7°C (44.6°F), the pump's thermometer is broken.
1. The water temperature is over 48°C (119°F).
2. If the water temperature is lower than
45°C (113°F), the pump's thermometer is broken.
1. The pump's thermometer connectors are not
working properly.
2. The pump's thermometer is broken.
1. The ambient temperature is over 50°C (122°F) or
the pump is directly under the sunshine.
2. The thermal cut-out is broken.
The fuse is disconnected.
The signal line between control panel and power
board is not well connected.
HYDROJET PRO
Note that the timer is one time per use - the user sets the duration of the heating cycle, and
how many hours from now the heating cycle begins. The timer does NOT repeat until reset.
Celsius/Fahrenheit Toggle
The temperature can be displayed in either Celsius or Fahrenheit.
Temperature Adjustment Buttons
Pressing the Temperature Increase or Decrease buttons will cause the LED to flash.
When it is flashing you can adjust to the desired temperature setting. If you hold these
buttons down, the values will rapidly increase or decrease. The new and desired
temperature setting will remain on the LED display for 3 seconds to confirm the new value.
NOTE: The default temperature is 35°C (95°F).
NOTE: Temperature adjustment ranges from 20°C (68°F) to 40°C (104°F).
Power-Saving Timer LED
This LED flashing means you are setting the heating duration. The light will be on when
the heating function starts to work.
This LED flashing means you are setting the number of hours FROM NOW when the
heater will activate. When the light is on, the Power-Saving Timer function is set.
On/Off Button
Press this button for 2 seconds to active the control panel buttons and the light turns to green.
Press this button for 2 seconds to turn off all currently activated functions.
LED Display
Once powered up, the LED displays the current water temperature automatically.
After 72 hours of filtration (without using the power saving timer function), the pump
will hibernate and flash "End" with the current water temperature. When the pump is
hibernating both the heating and water filter functions are disabled. To re-active the
pump press lock/unlock button for 3 seconds.
NOTE: The water heat rate may change in the below conditions:
· When the outdoor temperature is below 15°C (59°F).
· If the cover is not in position when the heating function is activated.
NOTE: To display the current water temperature, run the filter system for at least a minute. The
water temperature as tested by an external thermometer may vary from the temperature as
displayed on the spa panel due to the differing positions of the measurement devices.
1. Unplug the pump, strike the side of the pump firmly (but not violently), and plug
it back in.
2. To get assistance visit our website www.bestwaycorp.com support section.
1. Remove the two stopper caps before starting the heating system. Refer to the
Assembly section in the User's Manual.
2. Remove the filter set from inside the pool and push the filter or heat button. If no
alarm appears, clean or change the filter cartridges and re-install the filter set
inside the pool.
3. To get assistance visit our website www.bestwaycorp.com support section.
appears, the
1. The spa is not designed to operate with water temperatures lower than 4ºC (40°F).
Unplug the pump and only re-start the pump when the water temperature reaches
6°C (43°F).
2. To get assistance visit our website www.bestwaycorp.com support section.
1. The spa is not designed to operate with water temperatures greater than
40°C (104°F). Unplug the pump and only re-start the pump when the water
temperature reaches 38°C (100°F) or lower.
2. To get assistance visit our website www.bestwaycorp.com support section.
To get assistance visit our website www.bestwaycorp.com support section.
1. Unplug the pump, and put the plug in a dry, cool place. Only re-start the pump
when the water temperature reaches 34°C (93.2°F) or lower.
2. To get assistance visit our website www.bestwaycorp.com support section.
To get assistance visit our website www.bestwaycorp.com support section.
To get assistance visit our website www.bestwaycorp.com support section.
8
Solutions