Operation
SETTING THE DATE AND TIME
The date and time must be set when the expansion with RTC is used for delayed start (parameter P20 = 2).
With the card OFF, press the CLOCK key for 3 seconds, and the display will show the label dd followed by the
day of the week from 1 to 7 (1= Monday, 7 = Sunday). Use the UP and DOWN keys to set the day of the week
and confirm by pressing the CLOCK key. Set the hours (label hh) and minutes (label mm) in the same way.
After confirming the minutes with the CLOCK key, the card will return to OFF.
NOTE: if P20=2, but the correct expansion is not installed (with RTC) an error is displayed (RTC label
flashing) at the end of the date and time setting procedure.
SETTING DELAYED START
The delayed start can be set only when the card is on and the timer is not being used for counting. Delayed
start can be set for the same day and for the following 6 days (for example, on Wednesday it is possible to
set the programmed start until maximum next Tuesday). From the day on which the first delayed start is set,
the card will turn on EVERY DAY at the set time until the delayed start is turned off. Press the CLOCK key for
3 seconds, the display will show the flashing dd label followed by the day of the week from 0 to 7 (0=delayed
start off, 1=Monday, 7=Sunday). Use the UP and DOWN keys to set the day of the week and confirm by
pressing the CLOCK key. Set the hours (flashing hh label) and minutes (flashing mm label) in the same way.
After confirming the minutes with the CLOCK key, the card will turn OFF and with the clock icon on and the
central dotpoints flashing. To display the programmed start date, press the CLOCK key and the day of the
week, time and minutes of the programmed start time will be displayed. The card can be used by pressing the
ON/OFF key and setting it to the on status. If the card is turned off, the indication of the delayed start will be
redisplayed (flashing dotpoints and clock icon on). To disable the programmed start, turn on the card, access
the delayed start setting and disable it by setting dd to zero.
NOTE: If the card turns on in error because the user forgot to turn off the daily delayed start, the oven
will turn off automatically after P23 hours after starting if no key is pressed. Set P23=0 to disable this
function.
USE OF EXAUSTER VALVE
By the exhauster valve the operator can regulate the baking steams and fumes flow out from the baking
chamber, while in the same the heat is kept. It is advisable to keep the valve fully closed when the oven is
under heating; so, the set temperature is reached in shortest possible time. While baking regulate the valve
according to the exigencies.
SHUT DOWN PHASE
To shut down the oven, press the power button on the digital control panel and then turn the main switch to the
position "0".
11